Matrix-Spike Mix, 200 µg/mL, Methanol:Methylenchlorid (80:20), 5 mL/Ampulle, 15er Pack

Katalognummer 31687-15
No Image Found

Matrix-Spike Mix, 200 µg/mL, Methanol:Methylenchlorid (80:20), 5 mL/Ampulle, 15er Pack

Überblick

Beschreibung

Acenaphthene (83-32-9)
Acenaphthylene (208-96-8)
Aniline (62-53-3)
Anthracene (120-12-7)
Azobenzene (103-33-3)*
Benz[a]anthracene (56-55-3)
Benzo[a]pyrene (50-32-8)
Benzo[b]fluoranthene (205-99-2)
Benzo[g,h,i]perylene (191-24-2)
Benzo[k]fluoranthene (207-08-9)
Benzyl alcohol (100-51-6)
Benzyl butyl phthalate (85-68-7)
Bis(2-ethylhexyl)adipate (103-23-1)
Bis(2-chloroethoxy)methane (111-91-1)
Bis(2-chloroethyl)ether (111-44-4)
Bis(2-ethylhexyl)phthalate (117-81-7)
4-Bromophenyl phenyl ether (101-55-3)
Carbazole (86-74-8)
4-Chloroaniline (106-47-8)
4-Chloro-3-methylphenol (59-50-7)
2-Chloronaphthalene (91-58-7)
2-Chlorophenol (95-57-8)
4-Chlorophenyl phenyl ether (7005-72-3)
Chrysene (218-01-9)
Dibenz[a,h]anthracene (53-70-3)
Dibenzofuran (132-64-9)
1,2-Dichlorobenzene (95-50-1)
1,3-Dichlorobenzene (541-73-1)
1,4-Dichlorobenzene (106-46-7)
2,4-Dichlorophenol (120-83-2)
Diethylphthalate (84-66-2)
Dimethylphthalate (131-11-3)
2,4-Dimethylphenol (105-67-9)
1,2-Dinitrobenzene (528-29-0)
1,3-Dinitrobenzene (99-65-0)
1,4-Dinitrobenzene (100-25-4)
4,6-Dinitro-2-methylphenol (Dinitro-o-cresol) (534-52-1)
2,4-Dinitrophenol (51-28-5)
2,4-Dinitrotoluene (121-14-2)
2,6-Dinitrotoluene (606-20-2)
Di-n-butyl phthalate (84-74-2)
Di-n-octyl phthalate (117-84-0)
Diphenylamine (122-39-4)†
Fluorene (86-73-7)
Fluoranthene (206-44-0)
Hexachlorobenzene (118-74-1)
Hexachlorobutadiene (87-68-3)
Hexachlorocyclopentadiene (77-47-4)
Hexachloroethane (67-72-1)
Indeno[1,2,3-cd]pyrene (193-39-5)
Isophorone (78-59-1)
1-Methylnaphthalene (90-12-0)
2-Methylnaphthalene (91-57-6)
2-Methylphenol (o-cresol) (95-48-7)
3-Methylphenol (m-cresol) (108-39-4)
4-Methylphenol (p-cresol) (106-44-5)
Naphthalene (91-20-3)
2-Nitroaniline (88-74-4)
3-Nitroaniline (99-09-2)
4-Nitroaniline (100-01-6)
Nitrobenzene (98-95-3)
2-Nitrophenol (88-75-5)
4-Nitrophenol (100-02-7)
N-Nitrosodimethylamine (62-75-9)
N-Nitroso-di-n-propylamine (621-64-7)
2,2'-Oxybis(1-chloropropane) (108-60-1)
Pentachlorophenol (87-86-5)
Phenanthrene (85-01-8)
Phenol (108-95-2)
Pyrene (129-00-0)
Pyridine (110-86-1)
2,3,4,6-Tetrachlorophenol (58-90-2)
2,3,5,6-Tetrachlorophenol (935-95-5)
1,2,4-Trichlorobenzene (120-82-1)
2,4,5-Trichlorophenol (95-95-4)
2,4,6-Trichlorophenol (88-06-2)

* 1,2-Diphenylhydrazin (in der Liste 8270 aufgeführter Analyt) zersetzt sich im Injektor zu Azobenzol (Gemischkomponente).

† N-Nitrosodiphenylamin ist eine reaktive Spezies, die eine vorzeitige Zersetzung anderer Verbindungen in der Mischung auslösen kann. Aus diesen Gründen wird bei der Herstellung dieser Mischung Diphenylamin verwendet.

Spezifikationen

Produktspezifikationen
Katalognummer
31687-15
Produktname
Matrix-Spike Mix, 200 µg/mL, Methanol:Methylenchlorid (80:20), 5 mL/Ampulle, 15er Pack
Can't find what you're looking for?
Kundenspezifische Referenzstandards

Benötigen Sie einen kundenspezifischen Referenzstandard? Verwenden Sie dieses Formular, um ein individuelles Angebot anzufordern.