Restek
Accueil / Centre de ressources / Documentation technique / Packed Micropacked Column Information

Packed & Micropacked Column Information

Table I: For specific applications, we recommend using these optimized columns for better method performance. Click on the column name for product specifications and easy online ordering.

Application Column Feature Benefit

ASTM Method D3606

D3606 Application Column Set

Column 1: Backflush column, 6' (1.8 m), 1/8" OD, 2.0 mm ID; Column 2: proprietary packing, 15.5' (4.7 m), 1/8" OD, 2.0 mm ID

Excellent separation of ethanol and benzene.

Reliably meets method requirements.

Refinery Gases

2abc Refinery Gas Column Set

Backflush Column

Optimized three-column set. (Backflush column sold separately.)

Elutes C5 hydrocarbons before C1-C4 hydrocarbons for optimized resolution.

Unsaturated Light Hydrocarbons

n-Octane on Res-Sil C Column

Unique selectivity for unsaturated hydrocarbons.

Excellent resolution of unsaturated light hydrocarbons gives increased data accuracy.

cis-2-Butene and 1,3-Butadiene

OPN on Res-Sil C Column

Optimized selectivity for cis-2-butene and 1,3-butadiene resolution.

Increased data accuracy.

Permanent Gases

ShinCarbon ST Columns
Packed / Micropacked

Optimized selectivity for permanent gas resolution without cryogenic cooling. Preconditioned.

Increases productivity.

Low-Level Sulfurs

Rt-XLSulfur Columns
Packed / Micropacked

Highly inert for ppbv levels of sulfur. Eliminates need for PTFE tubing.

Increased data accuracy for low-level sulfur analysis. Eliminates need for a special GC setup.

 

Table II: Select the packed column configuration that fits your instrument from the options below and add the corresponding suffix to any standard part number.

(Note that small OD columns [1/16” or less] do not require a suffix.)

Suffix Configuration

-800

General

-810

Agilent Standard

-811

Agilent 6850

-820

Varian Standard

-821

Varian 3800

-830

PE 900-3920; Sigma 1,2,3

-840

PE Standard

-845

ABB

-850

Shimadzu 14A, 2014

-851

Shimadzu 8A

-853

Shimadzu 17A, 2010

-860

Thermo TRACE 2000

-875

Analytical Controls

-890

Gow Mac 590

-891

Gow Mac 550

-893

Gow Mac 816

-895

SRI 8610C

 

Complete your column with one of our fitting kits.

Option* Description

Kit 1S

Fitting Kit: 1/4" Brass Nuts,
1/4" to 1/8" V/G Reducing Ferrules

Kit 2S

Fitting Kit: 1/4" Brass Nuts,
1/4" to 3/16" V/G Reducing Ferrules

Kit A

Fitting Kit: 1/8" Brass Nuts,
1/8" V/G Ferrules

Kit B

Fitting Kit: 1/8" Brass Nuts,
1/8" Brass Front & Back Ferrules

Kit B2

Fitting Kit: 1/4" Brass Nuts,
1/4" Brass Front & Back Ferrules

Kit C

Fitting Kit: 1/8" SS Nuts,
1/8" SS Front & Back Ferrules

Kit D

Fitting Kit: 1/8" SS Nuts,
1/8" V/G Ferrules

Kit E

Fitting Kit: 1/4" SS Nuts,
1/4" to 1/8" V/G Reducing Ferrules

Kit F

Fitting Kit: 1/4" SS Nuts,
1/4" to 3/16" V/G Reducing Ferrules

Kit G

Fitting Kit: 1/4" SS Nuts,
1/4" V/G Ferrules

Kit VNICKEL

Fitting Kit: 1/8" VCR fittings (Nickel)
(Silver soldered onto the column)

Kit VSS

Fitting Kit: 1/8" VCR fitting (SS)
(Silver soldered onto the column)

Preconditioning

Optional for each finished column

*Some options available at additional cost.

 

PCOT3225C-UNV