Restek
Risorse utili / Libreria tecnica / ASTM Petrochemical Method Chromatography Product Guide

ASTM Petrochemical Method Chromatography Product Guide

Proven, Integrated Solutions and Veteran Expertise for Your Petrochemical & Chemical Analyses

articleBanner

Restek is your ideal partner for integrated petrochemical solutions, and the following ASTM method product guide will help you quickly pick the right GC columns and reference standards for SimDist, DHA, finished gasoline, and other common petroleum analyses.

If you have any questions or need more information contact one of our in-house petroleum experts for assistance.

(High-Temperature) Simulated Distillation (SimDist)

Method #

Method Title

Restek Column(s)

Restek Reference
Standard(s)

Chromatogram#

D2887

Standard Test Method for Boiling Range Distribution of Petroleum Fractions by Gas Chromatography (C5–C44)

MXT-2887, Siltek-treated stainless steel
10 m x 0.53 mm x 2.65 µm
cat.# 70199

or

MXT-1HT SimDist, Siltek-treated stainless steel
10 m x 0.53 mm x 2.65 µm
cat.# 70132

or

Rtx-2887 Column
10 m x 0.53 mm x 2.65 µm
cat.# 10199

 

ASTM D2887-12 Calibration Standards
cat.# 31674

Polywax Standards
cat.# 36224–36227

D2887 Calibration Mix
cat.# 31222

GC_PC00750

D2887B Accelerated

Standard Test Method for Boiling Range Distribution of Petroleum Fractions by Gas Chromatography (C5–C44)

MXT-1HT SimDist Column
10 m x 0.53 mm x 0.88 µm
cat.# 70134

or

MXT-1HT SimDist Column
5 m x 0.53 mm x 2.65 µm
custom column #573912

ASTM D2887-12 Calibration Standards
cat.# 31674

Polywax Standards
cat.# 36224–36227

D2887 Calibration Mix
cat.# 31222

GC_PC1303

D7213

Standard Test Method for Boiling Range Distribution of Petroleum Distillates in the Boiling Range from 100 to 615 °C by Gas Chromatography (C5–C60)

MXT-1HT SimDist, Siltek-treated stainless steel
5 m x 0.53 mm x 0.10 µm
cat.# 70112

or

MXT-1HT SimDist, Siltek-treated stainless steel
5 m x 0.53 mm x 0.20 µm
cat.# 70115

or

MXT-1HT SimDist, Siltek-treated stainless steel
5 m x 0.53 mm x 0.88 µm
cat.# 70131

Request today

GC_PC1285

GC_PC1191

D6352

Standard Test Method for Boiling Range Distribution of Petroleum Distillates in Boiling Range from 174 to 700 °C by Gas Chromatography (C10–C90)

MXT-1HT SimDist, Siltek-treated stainless steel
5 m x 0.53 mm x 0.10 µm
cat.# 70112

or

MXT-1HT SimDist, Siltek-treated stainless steel
5 m x 0.53 mm x 0.20 µm
cat.# 70115

Polywax Standards
cat.# 36224–36227

GC_PC1188

D7398

Standard Test Method for Boiling Range Distribution of Fatty Acid Methyl Esters (FAME) in the Boiling Range from 100 to
615 °C by Gas Chromatography

MXT-1HT SimDist, Siltek-treated stainless steel
5 m x 0.53 mm x 0.88 µm
cat.# 70131

Polywax Standards
cat.# 36224–36227

 

GC_PC1285

D7500

Standard Test Method for Determination of Boiling Range Distribution of Distillates and Lubricating Base Oils in Boiling Range from 100 to 735 °C by Gas Chromatography (C7–C110)

MXT-1HT SimDist, Siltek-treated stainless steel
5 m x 0.53 mm x 0.10 µm
cat.# 70112

or

MXT-1HT SimDist, Siltek-treated stainless steel
5 m x 0.53 mm x 0.20 µm
cat.# 70115

Polywax Standards
cat.# 36224–36227

 

GC_PC1164

GC_PC1165

D7169

Standard Test Method for Boiling Point Distribution of Samples with Residues Such as Crude Oils and Atmospheric and Vacuum Residues by High-Temperature Gas Chromatography

MXT-1HT SimDist, Siltek-treated stainless steel
5 m x 0.53 mm x 0.10 µm
cat.# 70112

or

MXT-1HT SimDist, Siltek-treated stainless steel
5 m x 0.53 mm x 0.20 µm
cat.# 70115

Polywax Standards
cat.# 36224–36227

 

GC_PC1308

D7096

(replaces D3710)

Standard Test Method for Determination of the Boiling Range Distribution of Gasoline by Wide-Bore Capillary Gas Chromatography

MXT-1, Siltek-treated stainless steel
15 m x 0.53 mm x 5.00 µm
cat.# 70177

or

MXT-1, Siltek-treated stainless steel
30 m x 0.53 mm x 5.00 µm
cat.# 70179

Request today

or

D3710-95 Calibration Mix
cat.# 31223

GC_PC1326

GC_PC1327

GC_PC1328

Detailed Hydrocarbon Analysis (DHA)

Method #

Method Title

Restek Column(s)

Restek Reference
Standard(s)

Chromatogram#

D5134

Standard Test Method for Detailed Analysis of Petroleum Naphthas through n-Nonane by Capillary Gas Chromatography

Rtx-DHA-50
50 m x 0.20 mm x 0.50 µm
cat.# 10147

Request today

GC_PC1318

GC_PC1319

GC_PC1320

D6729

Standard Test Method for Determination of Individual Components in Spark Ignition Engine Fuels by 100-Meter Capillary High-Resolution Gas Chromatography

Rtx-DHA-100
100 m x 0.25 mm x 0.50 µm
cat.# 10148

DHA Standards
cat.# 33034
cat.# 30725–30731

GC_PC1322

GC_PC1323

GC_PC1324

GC_PC1325

GC_PC1330

D6730

Standard Test Method for Determination of Individual Components in Spark Ignition Engine Fuels by 100–Meter Capillary (with precolumn) High-Resolution Gas Chromatography

Rtx-DHA-100
100 m x 0.25 mm x 0.50 µm
cat.# 10148

and

Rtx-5 DHA Tuning
5 m x 0.25 mm x 1.00 µm
cat.# 10165

DHA Standards
cat.# 33034
cat.# 30725–30731

GC_PC1284

D6733

Standard Test Method for Determination of Individual Components in Spark Ignition Engine Fuels by 50-Meter Capillary High-Resolution Gas Chromatography

Rtx-DHA-50
50 m x 0.20 mm x 0.50 µm
cat.# 10147

DHA Standards
cat.# 33034
cat.# 30725–30731

 

Finished Gasoline

Method #

Method Title

Restek Column(s)

Restek Reference
Standard(s)

Chromatogram#

D3606

Standard Test Method for Determination of Benzene and Toluene in Spark Ignition Fuels by Gas Chromatography

D3606 Application 2-Column Set
cat.# 83606A

Specified in the D3606 method addendum — includes:

- Column 1: Backflush column
6' (1.8 m), 1/8" OD, 2.0 mm ID

and

- Column 2: proprietary packing
15.5' (4.7 m), 1/8" OD, 2.0 mm ID

Request today

GC_PC1366
GC_PC1372

D4815

Standard Test Method for Determination of MTBE, ETBE, TAME, DIPE, tertiary-Amyl Alcohol, and C1 to C4 Alcohols in Gasoline by Gas Chromatography (Oxygenates)

Micropacked with 20% TCEP on 80/100 Chromosorb PAW
0.56 m x 0.75 mm ID x 1/16" OD
cat.# 19040

and

Rtx-1
30 m x 0.53 mm x 3.00 µm
cat.# 10185

Request today

GC_PC00194

D5580

Standard Test Method for Determination of Benzene, Toluene, Ethylbenzene, p/m-Xylene, o-Xylene, C9 and Heavier Aromatics, and Total Aromatics in Finished Gasoline by Gas Chromatography

Micropacked with 20% TCEP on 80/100 Chromosorb PAW
0.56 m x 0.75 mm ID x 1/16" OD
cat.# 19040

and

Rtx-1
30 m x 0.53 mm x 5.00 µm
cat.# 10179

Request today

 

D5501

Standard Test Method for Determination of Ethanol Content of Denatured Fuel Ethanol by Gas Chromatography

Rtx-DHA-150
150 m x 0.25 mm x 1.00 µm
cat.# 10149

or

Rtx-DHA-100
100 m x 0.25 mm x 0.50 µm
cat.# 10148

Request today

GC_PC1144

D8071

Standard Test Method for Determination of Hydrocarbon Group Types and Select Hydrocarbon and Oxygenate Compounds in Automotive Spark-Ignition Engine Fuel Using Gas Chromatography with Vacuum Ultraviolet Absorption Spectroscopy Detection (GC-VUV)

Rxi-1ms
30 m x 0.25 mm x 0.25 µm
cat.# 13323

 

Request today

GC_PC1358

Biodiesel

Method #

Method Title

Restek Column(s)

Restek Reference
Standard(s)

Chromatogram#

D6584

Test Method for Determination of Free and Total Glycerin in B-100 Biodiesel Methyl Esters by Gas Chromatography

MXT-Biodiesel TG, Siltek-treated stainless steel
14 m x 0.53 mm x 0.16 µm
with 2 m Integra-Gap
cat.# 70289

or

MXT-Biodiesel TG, Siltek-treated stainless steel
15 m x 0.32 mm x 0.10 µm
with 2 m x 0.53 mm retention gap
cat.# 70291

or

Rtx-Biodiesel TG
15 m x 0.32 mm x 0.10 µm
with 2 m x 0.53 mm retention gap
cat.# 10293

Biodiesel Standards
cat.# 31880
cat.# 33020–33026
cat.# 33032–33033

GC_PC1293

GC_PC00969

Jet Fuel

Method #

Method Title

Restek Column(s)

Restek Reference
Standard(s)

Chromatogram#

D8267

Standard Test Method for Determination of Saturated Hydrocarbon, Aromatic, and Diaromatic Content of Aviation Turbine Fuels Using Gas Chromatography with Vacuum Ultraviolet Absorption Spectroscopy Detection (GC-VUV)

Rxi-1ms
30 m x 0.25 mm x 0.25 µm
cat.# 13323

 

Request today

GC_PC1359

Natural Gas

Method #

Method Title

Restek Column(s)

Restek Reference
Standard(s)

Chromatogram#

D1945

Standard Test Method for Analysis of Natural Gas by Gas Chromatography

MXT-Msieve 5A, Siltek-treated stainless steel
30 m x 0.53 mm x 50 µm
cat.# 79723-273

and

MXT-Q-BOND, Siltek-treated stainless steel
30 m x 0.53 mm x 20 µm
cat.# 79716-273

Natural Gas Standards
cat.# 34438–34440

GC_PC1182

Refinery Gas

Method #

Method Title

Restek Column(s)

Restek Reference
Standard(s)

Chromatogram#

D2163

Standard Test Method for Determination of Hydrocarbons in Liquefied Petroleum (LP) Gases and Propane/Propene Mixtures by Gas Chromatography

Rt-Alumina BOND/Na2SO4
50 m x 0.53 mm x 10 µm
cat.# 19756

Refinery Gas Standards
cat.# 34441–34443

GC_PC1309

GC_PC1310

UOP 539

Standard Practice for Analysis of Reformed Gas by Gas Chromatography

2abc Refinery Gas Packed Column Set
cat.# 88000-875

or

MXT-Msieve 5A, Siltek-treated stainless steel
30 m x 0.53 mm x 50 µm
- cat.# 79723-273

and

MXT-Q-BOND, Siltek-treated stainless steel
30 m x 0.53 mm x 20 µm
cat.# 79716

Request today

GC_PC1182

Impurities

Method #

Method Title

Restek Column(s)

Restek Reference
Standard(s)

Chromatogram#

D2593

Standard Test Method for Butadiene Purity and Hydrocarbon Impurities by Gas Chromatography

Rt-Alumina BOND/MAPD
50 m x 0.53 mm x 10 µm
cat.# 19778

Refinery Gas Standard #5
cat.# 34443

GC_PC1202

D2712

Standard Test Method for Hydrocarbon Traces in Propylene Concentrates by Gas Chromatography

Rt-Alumina BOND/KCl
50 m x 0.53 mm x 10 µm
cat.# 19760

Refinery Gas Standard #5
cat.# 34443

GC_PC01142

D6159

Standard Test Method for Determination of Hydrocarbon Impurities in Ethylene by Gas Chromatography

Rt-Alumina BOND/KCl
50 m x 0.53 mm x 10 µm
cat.# 19760

and

Rtx-1
30 m x 0.53 mm x 5.00 µm
cat.# 10179

Refinery Gas Standard #5
cat.# 34443

GC_PC01110

D5441

Standard Test Method for Analysis of Methyl Tert-Butyl Ether (MTBE) by Gas Chromatography

Rtx-DHA-100
100 m x 0.25 mm x 0.50 µm
cat.# 10148

or

Rtx-DHA-50
50 m x 0.20 mm x 0.50 µm
cat.# 10147

or

Rtx-DHA-150
150 m x 0.25 mm x 1.0 µm
cat.# 10149

Request today

GC_PC1268

GC_PC1270

GC_PC1269

Sulfur

Method #

Method Title

Restek Column(s)

Restek Reference
Standard(s)

Chromatogram#

D6228

Standard Test Method for Determination of Sulfur Compounds in Natural Gas and Gaseous Fuels by Gas Chromatography and Flame Photometric Detection

Rtx-1
60 m x 0.53 mm x 7.00 µm
cat.# 10193

or

MXT-1, Siltek-treated stainless steel
60 m x 0.53 mm x 7.00 µm
cat.# 70193

or

Rtx-1
60 m x 0.32 mm x 5.0 µm
cat.# 10180

Request today

GC_PC1223

D5623

Standard Test Method for Sulfur Compounds in Light Petroleum Liquids by Gas Chromatography and Sulfur Selective Detection

Rtx-1
30 m x 0.32 mm x 4.00 µm
cat.# 10198

Request today
(gasliquid)

GC_PC1271

GC_PC00198

Industrial Chemicals

Method #

Method Title

Restek Column(s)

Restek Reference
Standard(s)

Chromatogram#

D5917

Standard Test Method for Trace Impurities in Monocyclic Aromatic Hydrocarbons by Gas Chromatography and External Calibration

Stabilwax
60 m x 0.32 mm x 0.25 µm
cat.# 10627

Request today

GC_PC1355
GC_PC1352
GC_PC1353
GC_PC1354

D7266

Standard Test Method for Analysis of Cyclohexane by Gas Chromatography (External Standard)

Rtx-DHA-100
100 m x 0.25 mm x 0.50 µm
cat.# 10148

Request today

GC_PC1356

D7504

Standard Test Method for Trace Impurities in Monocyclic Aromatic Hydrocarbons by Gas Chromatography and Effective Carbon Number

Stabilwax
60 m x 0.32 mm x 0.25 µm
cat.# 10627

Request today

GC_PC1352
GC_PC1353
GC_PC1354
GC_PC1355

D7871

Standard Test Method for Analysis of Cyclohexane by Gas Chromatography (Effective Carbon Number)

Rtx-DHA-100
100 m x 0.25 mm x 0.50 µm
cat.# 10148

Request today

GC_PC1356

D7011

Standard Test Method for Determination of Trace Thiophene in Refined Benzene by Gas Chromatography and Sulfur Selective Detection

Rtx-WAX
30 m x 0.32 mm x 1.00 µm
cat.# 12454

Request today

GC_PC1357

D6144

Standard Test Method for Analysis of AMS (a-Methylstyrene) by Capillary Gas Chromatography

Rtx-1
60 m x 0.32 mm x 1.00 µm
cat.# 10157

Request today

GC_PC1351

D7057

Standard Test Method for Analysis of Isopropylbenzene (Cumene) by Gas Chromatography (External Standard)

Rtx-1
60 m x 0.32 mm x 1.00 µm
cat.# 10157

Request today

GC_PC1350

D5310

Standard Test Method for Tar Acid Composition by Capillary Gas Chromatography

Rxi 5MS
30 m x 0.53 mm x 1.00 µm
cat.# 13423

Request today

GC_PC1371

D3329

Standard Test Method for Purity of Methyl Isobutyl Ketone by Gas Chromatography

Stabilwax
30 m x 0.25 mm x 1.00 µm
cat. #10655

Request today

GC_PC1373

D7090

Standard Test Method for Purity of Isophorone by Capillary Gas Chromatography

Rtx - WAX
30 m x 0.32 mm x 0.5 µm
cat.# 12439

Request today

GC_PC1369

D3893

Standard Test Method for Purity of Methyl Amyl Ketone and Methyl Isoamyl Ketone by Gas Chromatography

Stabilwax
30 m x 0.53 mm x 1.00 µm
cat. #10655

Request today

 

 

PCAR2082I-UNV