Generatore d’aria zero Parker, modello HPZA-7000, capacità 7000 cc/min
n° catalogo 20681
Ordine
International power cords are available. Contact Customer Service to order.
![Generatore d’aria zero Parker, modello HPZA-7000, capacità 7000 cc/min](/ccstore/v1/images/?source=/file/v5723012306696595085/products/grp-parker-zero-air-hpza-generators.jpg&height=200&width=200)
Generatore d’aria zero Parker, modello HPZA-7000, capacità 7000 cc/min
Panoramica
Caratteristiche e benefici
- Trasforma l’aria compressa interna in aria ultrapura.
- Rimuove gli idrocarburi a meno di 0,1 ppm mediante ossidazione catalitica.
- Funziona a 40–125 psi (276–862 kPa).
- Il ROI tipico è inferiore a un anno, a seconda dei costi della bombola.
- Si installa facilmente e presenta un ingombro ridotto.*
- I kit di manutenzione comprendono una fornitura di un anno di prefiltri e filtro finale.
Descrizione del prodotto
Specifications for Parker Balston Zero Air Generators
Maximum Zero Air Flow Rate: | 75-83NA HPZA-3500 HPZA-7000 HPZA-18000 HPZA-30000 |
1.0 L/min 3.5 L/min 7.0 L/min 18 L/min 30 L/min |
Outlet Hydrocarbon Concentration (as methane): | 75-83NA HPZA-30000 Other Models |
< 0.1 ppm < 0.1 ppm < 0.05 ppm |
Minimum/Maximum Inlet Air Pressure: | 40 psig/125 psig (276/862 kPa) | |
Maximum Inlet Hydrocarbon Concentration (as methane): | 100 ppm | |
Pressure Drop at Maximum Flow Rate: | 4 psi (28 kPa) differential | |
Maximum Inlet Air Temperature: | 78°F (25°C) | |
Inlet/Outlet Ports: | 1/4" NPT (female) | |
Start-up Time to Specified Hydrocarbon Concentration: | 45 minutes | |
Electrical Requirements: | 75-83NA HPZA-3500, HPZA-7000 HPZA-18000, HPZA-30000 |
120 VAC/60 Hz, 0.5 amps 120, 220, 230, 240 VAC/60 Hz, 2.0 amps 120, 220, 230, 240 VAC/60 Hz, 4.0 amps |
Dimensions: | 75-83NA Other Models |
10" h x 12" w x 3" d (25 cm x 30 cm x 8 cm) 16" h x 11" w x 13" d (42 cm x 27 cm x 34 cm) |
Shipping Weight: | 75-83NA Other Models |
7 lb (3 kg) 41 lb (19 kg) |
Model | Number of FIDs (based on a 450 cc/min fuel air rate) |
75-83NA | Up to 2 |
HPZA-3500 | Up to 8 |
HPZA-7000 | Up to 16 |
HPZA-18000 | Up to 40 |
HPZA-30000 | Up to 66 |
Specifiche tecniche
Specifiche tecniche
n° catalogo
20681
Nome Prodotto
Generatore d’aria zero Parker, modello HPZA-7000, capacità 7000 cc/min