![Restek](/file/general/restek-logo.png)
Home / Gascromatografia / Purificatori di gas / Kit filtro per gas / Kit di pulizia carrier gas specifico per elio Super Clean a incastro e in linea, acciaio inox 1/4”
![Restek](/file/general/restek-logo.png)
![Kit di pulizia carrier gas specifico per elio Super Clean a incastro e in linea, acciaio inox 1/4” Kit di pulizia carrier gas specifico per elio Super Clean a incastro e in linea, acciaio inox 1/4”](/ccstore/v1/images/?source=/file/v8128361234279727802/products/22471.jpg&height=475&width=475&quality=0.8&outputFormat=JPEG)
Kit di pulizia carrier gas specifico per elio Super Clean a incastro e in linea, acciaio inox 1/4”
n° catalogo 22471
![Kit di pulizia carrier gas specifico per elio Super Clean a incastro e in linea, acciaio inox 1/4”](/ccstore/v1/images/?source=/file/v8128361234279727802/products/22471.jpg&height=200&width=200)
Kit di pulizia carrier gas specifico per elio Super Clean a incastro e in linea, acciaio inox 1/4”
Panoramica
Caratteristiche e benefici
- Purezza del gas in uscita garantita al 99,9999%.
- Raccordi Click-On per sostituire la cartuccia in modo semplice e senza perdite; ottone o acciaio inox, 1/4” o 1/8”.
- La trappola per gas tripla è ideale per purificare il carrier gas: contiene ossigeno, umidità e gorgogliatore di lavaggio per idrocarburi in un’unica cartuccia.
- La trappola per gas combustibile è ideale per purificare i gas combustibili del detector a ionizzazione di fiamma (FID), rimuovendo sia l’umidità che gli idrocarburi.
- La trappola per gas tripla specifica per l’elio è ideale per le analisi GC-MS: contiene ossigeno, umidità e gorgogliatore di lavaggio per idrocarburi in un’unica cartuccia.
Descrizione del prodotto
Specifications for Click-On Inline Super-Clean Purification Gas Traps
Click-On Traps measure: 8 1/2" x 1 1/4" (21.6 x 3.2 cm)
-----Capacity------ | ||||||||
Type of Filter | Gas Quality at Outlet |
Maximum Pressure | Maximum Flow (L/min.) |
Use for: | H20 (g) | O2 (mL) | Hydrocarbons (g) (as n-butane) |
Estimated Lifetime (years) |
Moisture cat.# 22467 |
>99.9999 | 11 bar 160 psi |
25 | Inert carrier gas Helium Air Hydrogen |
15 | NA | NA | >3 |
Oxygen cat.# 22468 |
>99.9999 | 11 bar 160 psi |
25 | Inert carrier gas Hydrogen |
NA | 2000 | NA | >3 |
Hydrocarbon cat.# 22466 |
>99.9999 | 11 bar 160 psi |
25 | Inert carrier gas Helium Air Hydrogen |
NA | NA | 24 | >3 |
Fuel Gas1 cat.# 22465 |
>99.9999 | 11 bar 160 psi |
25 | Inert carrier gas Helium Air Hydrogen |
7 | NA | 12 | >2 |
Triple2 cat.# 22464 |
>99.9999 | 11 bar 160 psi |
25 | Inert carrier gas Hydrogen |
4 | 1000 | 8 | >2 |
Helium-Specific Triple2 cat.# 22473 |
>99.9999 | 11 bar 160 psi |
25 | Helium | 4 | 1000 | 8 | >2 |
1 Removes hydrocarbons, moisture.
2 Removes hydrocarbons, moisture, oxygen.
Note:
Super-Clean Gas Filters are recommended for purifying noncorrosive gases with low concentrations of contaminants. The maximum concentration of oxygen in the incoming gas stream for oxygen purifiers is 0.5%.
Did you know?
Trap replacement depends on the quality of the incoming gas. Use the double connector and install an indicating cartridge after a trap to indicate when the trap should be replaced.
To prevent settling of desiccant, mount vertically, not horizontally.
Specifiche tecniche
Specifiche tecniche
n° catalogo
22471
Nome Prodotto
Kit di pulizia carrier gas specifico per elio Super Clean a incastro e in linea, acciaio inox 1/4”