Kit performance standard QuEChERS
n° catalogo 31152
![Kit performance standard QuEChERS](/ccstore/v1/images/?source=/file/v4986824488759114729/products/ampuls-blue_ph2_arm.jpg&height=200&width=200)
Kit performance standard QuEChERS
Panoramica
Caratteristiche e benefici
- Realizzati per essere utilizzati in tutti i metodi QuEChERS per l’analisi di pesticidi in frutta e verdura, incluso il metodo Original senza tampone, AOAC 2007.01 ed EN 15662.
- Il kit contiene pesticidi organoclorurati, organici azotati, organofosforici e carbammati comunemente utilizzati nella frutta e verdura.
- Sono inclusi composti volatili, polari, attivi, sensibili alle basi e non volatili per consentire una valutazione completa dell’efficienza QuEChERS in estrazione e purificazione e l’ottimizzazione delle condizioni strumentali GC e LC.
- Ideali per le valutazioni del metodo iniziali e le validazioni continue della performance dei metodi.
- Gli analiti sono divisi in tre ampolle in base alla compatibilità per una stabilità e shelf life ottimali.*
- Formulazioni precise migliorano la qualità dei dati e l’efficienza operativa: potrai dedicare più tempo all’analisi dei campioni e meno all’approvvigionamento e alla preparazione degli standard.
- Analizzati quantitativamente per confermare composizione e stabilità di ogni miscela.
*When combining compounds with different functionalities, chemical stability can be an issue. The analytes in this kit are separated into three mixes to ensure maximum long-term storage stability. For analysis, a fresh working standard should be prepared by combining the three kit mixes in a 1:1:1 ratio to prepare a 100 µg/mL working standard solution. Once blended, Restek does not recommend storing working standards or subsequent dilutions for future use.
Descrizione del prodotto
Contains 1 mL each of these mixtures. 300 µg/mL each in acetonitrile/acetic acid (99.9:0.1), 1 mL/ampul. Blend equal volumes of all three ampuls for a 100 µg/mL final solution.
31153: QuEChERS Performance Standard A (16 components)
Acephate (30560-19-1)
Azinphos methyl (86-50-0)
Chlorpyrifos (2921-88-2)
Coumaphos (56-72-4)
Diazinon (333-41-5)
Dichlofluanid (1085-98-9)
Dichlorvos (DDVP) (62-73-7)
Dimethoate (60-51-5)
Fenthion (55-38-9)
Malathion (121-75-5)
Methamidophos (10265-92-6)
Mevinphos (7786-34-7)
Omethoate (1113-02-6)
Phosalone (2310-17-0)
Pirimiphos methyl (29232-93-7)
Propargite (2312-35-8)
31154: QuEChERS Performance Standard B (7 components)
γ-BHC (Lindane) (58-89-9)
Chlorothalonil (1897-45-6)
4,4'-DDT (50-29-3)
Dicofol (Kelthane) (115-32-2)
Endosulfan sulfate (1031-07-8)
Endrin (72-20-8)
2-Phenylphenol (90-43-7)
31155: QuEChERS Performance Standard C (17 components)
Bifenthrin (82657-04-3)
Captan (133-06-2)
Carbaryl (Sevin) (63-25-2)
Cyprodinil (121552-61-2)
Deltamethrin (52918-63-5)
Fenhexamid (126833-17-8)
Fenpropathrin (39515-41-8)
Folpet (133-07-3)
Imazalil (35554-44-0)
Iprodione (36734-19-7)
Metalaxyl (57837-19-1)
Methiocarb (2032-65-7)
Myclobutanil (88671-89-0)
cis-Permethrin (61949-76-6)
trans-Permethrin (61949-77-7)
Thiabendazole (148-79-8)
Vinclozolin (50471-44-8)
31153: QuEChERS Performance Standard A (16 components)
Acephate (30560-19-1)
Azinphos methyl (86-50-0)
Chlorpyrifos (2921-88-2)
Coumaphos (56-72-4)
Diazinon (333-41-5)
Dichlofluanid (1085-98-9)
Dichlorvos (DDVP) (62-73-7)
Dimethoate (60-51-5)
Fenthion (55-38-9)
Malathion (121-75-5)
Methamidophos (10265-92-6)
Mevinphos (7786-34-7)
Omethoate (1113-02-6)
Phosalone (2310-17-0)
Pirimiphos methyl (29232-93-7)
Propargite (2312-35-8)
31154: QuEChERS Performance Standard B (7 components)
γ-BHC (Lindane) (58-89-9)
Chlorothalonil (1897-45-6)
4,4'-DDT (50-29-3)
Dicofol (Kelthane) (115-32-2)
Endosulfan sulfate (1031-07-8)
Endrin (72-20-8)
2-Phenylphenol (90-43-7)
31155: QuEChERS Performance Standard C (17 components)
Bifenthrin (82657-04-3)
Captan (133-06-2)
Carbaryl (Sevin) (63-25-2)
Cyprodinil (121552-61-2)
Deltamethrin (52918-63-5)
Fenhexamid (126833-17-8)
Fenpropathrin (39515-41-8)
Folpet (133-07-3)
Imazalil (35554-44-0)
Iprodione (36734-19-7)
Metalaxyl (57837-19-1)
Methiocarb (2032-65-7)
Myclobutanil (88671-89-0)
cis-Permethrin (61949-76-6)
trans-Permethrin (61949-77-7)
Thiabendazole (148-79-8)
Vinclozolin (50471-44-8)
Specifiche tecniche
Specifiche tecniche
n° catalogo
31152
Nome Prodotto
Kit performance standard QuEChERS