- Robust, low-flow pump optimized for sampling volatile organic compounds (VOCs) onto thermal desorption (TD) sorbent tubes.
- Small, lightweight, easy to use, and intrinsically safe—ideal for personal monitoring and a wide range of other air and gas sampling applications.
- Compatible with any TD tube (up to a max flow of 350 mL/min); automatically compensates for different impedances, ensuring constant flow rates with any sorbent packing.
- Allows constant flow sampling from 20–200 mL/min and constant pressure sampling from 1–350 mL/min.
- Easy to calibrate via a simple screw-operated flow adjustment.
- Rechargeable NiMH battery ensures stable performance for over 8 hours.
- Supplied in a convenient carrying case with charger (110–230 V*) and accessories.
Sampler Comparison Chart
ACTI-VOC Low-Flow TD Sampling Pump ![]() |
MTS-32 Multiple Tube Sequential Sampler![]() |
Easy-VOC Grab Sampler![]() |
|
Tube accommodation |
1 x 1/4" x 3 1/2" or 6 OD |
Up to 32 x 1/4" x 3 1/2" |
1 x 1/4" x 3 1/2" or 6 mm OD |
Analyte compatibility |
n-C3 to n-C32 |
n-C3 to n-C32 |
n-C3 to n-C32 |
Operation |
On/off switch |
Automated sequential |
Manual |
Power supply |
Battery |
Main or battery |
Manual |
Sample type |
Time integrated |
Time integrated |
Grab |
Sample flows |
20–200 mL/min (constant flow) |
5–100 mL/min |
100–400 mL/min |
Sample volumes |
Varies by analyte |
Varies by analyte |
50 mL minimum; may be increased indefinitely in increments of either 50 or 100 mL. Total volume varies by analyte. |
Sample times |
Minutes to hours |
Minutes to days |
Minutes |
Battery type |
Rechargeable NiMH battery |
Rechargeable 12 V lead-acid battery |
— |
Battery lifetime |
Over 8 hours (when fully charged) |
Over 40 hours (when fully charged) |
— |
Weight |
340 g (0.75 lb) |
7 kg (15.4 lb) |
350 g (0.77 lb) |
Dimensions |
6.4 cm (2.5") width x 11.8 cm (4.6") height x 3.5 cm (1.4") depth |
30 cm (11.8") width x 17 cm (6.7") height x 25 cm (9.8") depth |
4 cm (1.6") diameter x 25 cm (9.8") length with handle in. |