VOC MegaMix 131 Kit, 1 mL/ampul, 10 ampuls/kit
![VOC MegaMix 131 Kit, 1 mL/ampul, 10 ampuls/kit](/ccstore/v1/images/?source=/file/v6768706228713431366/products/ampul-0to2ml_ph_so_arm-trio.jpg&height=200&width=200)
VOC MegaMix 131 Kit, 1 mL/ampul, 10 ampuls/kit
概要
- Single kit comprised of 131 compounds commonly analyzed in volatiles testing, reducing sample prep time and variability.
- High analyte concentration allows for flexibility in constructing calibration solutions.
- Two independent lots available to meet your quality control requirements.
- Useful for EPA 8260 or other volatiles analyses.
Note: Pentachloroethane (Cat.# 30404) is provided as a separate standard in this kit in order to allow for running a system check of this standard before beginning your analyses or to provide flexibility in leaving this standard out of your calibration solutions if pentachloroethane does not need to be reported. Several issues can cause pentachloroethane to convert into tetrachloroethene during an analysis, and the resulting elevated level of tetrachloroethene and low-biased pentachloroethane response may lead to failed proficiency tests (PTs) when analyzing VOCs in solid waste by EPA Method 8260.
Contains one ampul of each of the following:
Cat.# 30152: 8260 MegaMix Calibration Mix, Revised
2000 µg/mL in Methanol, 1 mL/ampul
Compounds | CAS # |
Acetonitrile | 75-05-8 |
Acrylonitrile | 107-13-1 |
Allyl chloride (3-chloropropene) | 107-05-1 |
Benzene | 71-43-2 |
Bromobenzene | 108-86-1 |
Bromochloromethane | 74-97-5 |
Bromodichloromethane | 75-27-4 |
Bromoform | 75-25-2 |
n-Butylbenzene | 104-51-8 |
sec-Butylbenzene | 135-98-8 |
tert-Butylbenzene | 98-06-6 |
Carbon disulfide | 75-15-0 |
Carbon tetrachloride | 56-23-5 |
Chlorobenzene | 108-90-7 |
2-Chloroethanol | 107-07-3 |
Chloroform | 67-66-3 |
Chloroprene (2-chloro-1,3-butadiene) | 126-99-8 |
2-Chlorotoluene | 95-49-8 |
4-Chlorotoluene | 106-43-4 |
Dibromochloromethane | 124-48-1 |
1,2-Dibromo-3-chloropropane (DBCP) | 96-12-8 |
1,2-Dibromoethane (EDB) | 106-93-4 |
Dibromomethane | 74-95-3 |
1,2-Dichlorobenzene | 95-50-1 |
1,3-Dichlorobenzene | 541-73-1 |
1,4-Dichlorobenzene | 106-46-7 |
cis-1,4-Dichloro-2-butene | 1476-11-5 |
trans-1,4-Dichloro-2-butene | 110-57-6 |
1,1-Dichloroethane | 75-34-3 |
1,2-Dichloroethane | 107-06-2 |
1,1-Dichloroethene | 75-35-4 |
cis-1,2-Dichloroethene | 156-59-2 |
trans-1,2-Dichloroethene | 156-60-5 |
1,2-Dichloropropane | 78-87-5 |
1,3-Dichloropropane | 142-28-9 |
2,2-Dichloropropane | 594-20-7 |
1,1-Dichloropropene | 563-58-6 |
cis-1,3-Dichloropropene | 10061-01-5 |
trans-1,3-Dichloropropene | 10061-02-6 |
Diethyl ether (ethyl ether) | 60-29-7 |
1,4-Dioxane | 123-91-1 |
Ethylbenzene | 100-41-4 |
Ethyl methacrylate | 97-63-2 |
Hexachloro-1,3-butadiene | 87-68-3 |
Iodomethane (methyl iodide) | 74-88-4 |
Isobutyl alcohol (2-methyl-1-propanol) | 78-83-1 |
Isopropylbenzene (cumene) | 98-82-8 |
4-Isopropyltoluene (p-Cymene) | 99-87-6 |
Methacrylonitrile | 126-98-7 |
Methyl acrylate | 96-33-3 |
Methyl methacrylate | 80-62-6 |
Methylene chloride (dichloromethane) | 75-09-2 |
Naphthalene | 91-20-3 |
Nitrobenzene | 98-95-3 |
2-Nitropropane | 79-46-9 |
Propionitrile | 107-12-0 |
n-Propylbenzene | 103-65-1 |
Styrene | 100-42-5 |
1,1,1,2-Tetrachloroethane | 630-20-6 |
1,1,2,2-Tetrachloroethane | 79-34-5 |
Tetrachloroethene | 127-18-4 |
Tetrahydrofuran | 109-99-9 |
Toluene | 108-88-3 |
1,2,3-Trichlorobenzene | 87-61-6 |
1,2,4-Trichlorobenzene | 120-82-1 |
1,1,1-Trichloroethane | 71-55-6 |
1,1,2-Trichloroethane | 79-00-5 |
Trichloroethene | 79-01-6 |
1,2,3-Trichloropropane | 96-18-4 |
1,1,2-Trichlorotrifluoroethane (CFC-113) | 76-13-1 |
1,2,4-Trimethylbenzene | 95-63-6 |
1,3,5-Trimethylbenzene | 108-67-8 |
m-Xylene | 108-38-3 |
o-Xylene | 95-47-6 |
p-Xylene | 106-42-3 |
Cat.# 30676: Volatile MegaMix II
2000-10,000 µg/mL in Methanol, 1 mL/ampul
Compounds | CAS # | Conc (µg/mL) |
tert-Amyl alcohol | 75-85-4 | 10,000 |
tert-Amyl ethyl ether (TAEE) | 919-94-8 | 2000 |
tert-Amyl methyl ether (TAME) | 994-05-8 | 2000 |
Benzyl chloride | 100-44-7 | 2000 |
1-Butanol | 71-36-3 | 10,000 |
2-Butanol (sec-butyl alcohol) | 78-92-2 | 2000 |
tert-Butanol (TBA) | 75-65-0 | 10,000 |
Butyl acetate | 123-86-4 | 2000 |
1-Chlorohexane | 544-10-5 | 2000 |
3-Chlorotoluene | 108-41-8 | 2000 |
Cyclohexane | 110-82-7 | 2000 |
1,2-Diethylbenzene | 135-01-3 | 2000 |
1,3-Diethylbenzene | 141-93-5 | 2000 |
1,4-Diethylbenzene | 105-05-5 | 2000 |
Diisopropyl ether (DIPE) | 108-20-3 | 2000 |
Ethanol | 64-17-5 | 10,000 |
Ethyl acetate | 141-78-6 | 5000 |
Ethyl acrylate | 140-88-5 | 2000 |
Ethyl-tert-butyl ether (ETBE) | 637-92-3 | 2000 |
p-Ethyltoluene | 622-96-8 | 2000 |
n-Heptane (C7) | 142-82-5 | 2000 |
Hexachloroethane | 67-72-1 | 2000 |
n-Hexane (C6) | 110-54-3 | 2000 |
Isopropyl acetate | 108-21-4 | 2000 |
Methyl acetate | 79-20-9 | 5000 |
3-Methyl-1-butanol (isoamyl alcohol) | 123-51-3 | 2000 |
Methyl-tert-butyl ether (MTBE) | 1634-04-4 | 2000 |
Methylcyclohexane | 108-87-2 | 2000 |
1-Methylnaphthalene | 90-12-0 | 2000 |
2-Methylnaphthalene | 91-57-6 | 2000 |
4-Methyl-2-pentanol | 108-11-2 | 2000 |
1-Propanol | 71-23-8 | 10,000 |
2-Propanol (isopropanol) | 67-63-0 | 10,000 |
Propyl acetate | 109-60-4 | 2000 |
1,2,4,5-Tetramethylbenzene | 95-93-2 | 2000 |
1,3,5-Trichlorobenzene | 108-70-3 | 2000 |
1,2,3-Trimethylbenzene | 526-73-8 | 2000 |
2,2,4-Trimethylpentane (isooctane) | 540-84-1 | 2000 |
Cat.# 30006: VOA Calibration Mix #1
5000 µg/mL in P&T Methanol:Water (90:10), 1 mL/ampul
Compounds | CAS # |
Acetone | 67-64-1 |
2-Butanone (MEK) | 78-93-3 |
2-Hexanone | 591-78-6 |
4-Methyl-2-pentanone (MIBK) | 108-10-1 |
Cat.# 30678: Volatile Gases Standard
2000 µg/mL in Methanol, 1 mL/ampul
Compounds | CAS # |
Bromomethane (methyl bromide) | 74-83-9 |
1,3-Butadiene | 106-99-0 |
Chloroethane (ethyl chloride) | 75-00-3 |
Chloromethane (methyl chloride) | 74-87-3 |
Dichlorodifluoromethane (CFC-12) | 75-71-8 |
Methyl ether (dimethyl ether) | 115-10-6 |
Trichlorofluoromethane (CFC-11) | 75-69-4 |
Vinyl chloride | 75-01-4 |
Cat.# 30265: 2-Chloroethyl Vinyl Ether Standard
2000 µg/mL in Methanol, 1 mL/ampul
Compounds | CAS # |
2-Chloroethyl vinyl ether | 110-75-8 |
Cat.# 30646: Acrolein Standard
5000 µg/mL in Water, 1 mL/ampul
Compounds | CAS # |
Acrolein | 107-02-8 |
Cat.# 30677: Cyclohexanone Standard
10,000 µg/mL in Water, 1 mL/ampul
Compounds | CAS # |
Cyclohexanone | 108-94-1 |
Cat.# 30679: Epichlorohydrin Standard
2000 µg/mL in Methanol, 1 mL/ampul
Compounds | CAS # |
Epichlorohydrin (1-Chloro-2,3-epoxypropane) | 106-89-8 |
Cat.# 30404: Pentachloroethane Standard
2000 µg/mL, P&T Methanol, 1 mL/ampul
Compounds | CAS # |
Pentachloroethane | 76-01-7 |
Cat.# 30216: Vinyl Acetate Standard
2000 ug/mL in Methanol, 1 mL/ampul
Compounds | CAS # |
Vinyl acetate | 108-05-4 |