8270/Appendix IX Kit
8270/Appendix IX Kit
概要
U.S. DEA-exempted formulation—no additional customer permits or licensing are required to purchase within the U.S.
Simplify calibration with SVOC MegaMix reference standards kits that contain 150 (cat.# 31907) or 100 (cat.# 31908) of the most frequently analyzed semivolatiles.
Contains 1 mL each of these mixtures.
31850: 8270 MegaMix Standard
Acenaphthene (83-32-9)
Acenaphthylene (208-96-8)
Aniline (62-53-3)
Anthracene (120-12-7)
Azobenzene (103-33-3)*
Benz[a]anthracene (56-55-3)
Benzo[a]pyrene (50-32-8)
Benzo[b]fluoranthene (205-99-2)
Benzo[g,h,i]perylene (191-24-2)
Benzo[k]fluoranthene (207-08-9)
Benzyl alcohol (100-51-6)
Benzyl butyl phthalate (85-68-7)
Bis(2-chloroethoxy)methane (111-91-1)
Bis(2-chloroethyl)ether (111-44-4)
Bis(2-ethylhexyl)adipate (103-23-1)
Bis(2-ethylhexyl)phthalate (117-81-7)
4-Bromophenyl phenyl ether (101-55-3)
Carbazole (86-74-8)
4-Chloroaniline (106-47-8)
4-Chloro-3-methylphenol (59-50-7)
2-Chloronaphthalene (91-58-7)
2-Chlorophenol (95-57-8)
4-Chlorophenyl phenyl ether (7005-72-3)
Chrysene (218-01-9)
Dibenz[a,h]anthracene (53-70-3)
Dibenzofuran (132-64-9)
1,2-Dichlorobenzene (95-50-1)
1,3-Dichlorobenzene (541-73-1)
1,4-Dichlorobenzene (106-46-7)
2,4-Dichlorophenol (120-83-2)
Diethylphthalate (84-66-2)
2,4-Dimethylphenol (105-67-9)
Dimethylphthalate (131-11-3)
Di-n-butyl phthalate (84-74-2)
1,2-Dinitrobenzene (528-29-0)
1,3-Dinitrobenzene (99-65-0)
1,4-Dinitrobenzene (100-25-4)
4,6-Dinitro-2-methylphenol (Dinitro-o-cresol) (534-52-1)
2,4-Dinitrophenol (51-28-5)
2,4-Dinitrotoluene (121-14-2)
2,6-Dinitrotoluene (606-20-2)
Di-n-octyl phthalate (117-84-0)
Diphenylamine (122-39-4)†
Fluoranthene (206-44-0)
Fluorene (86-73-7)
Hexachlorobenzene (118-74-1)
Hexachlorobutadiene (87-68-3)
Hexachlorocyclopentadiene (77-47-4)
Hexachloroethane (67-72-1)
Indeno[1,2,3-cd]pyrene (193-39-5)
Isophorone (78-59-1)
1-Methylnaphthalene (90-12-0)
2-Methylnaphthalene (91-57-6)
2-Methylphenol (o-cresol) (95-48-7)
3-Methylphenol (m-cresol) (108-39-4)
4-Methylphenol (p-cresol) (106-44-5)
Naphthalene (91-20-3)
2-Nitroaniline (88-74-4)
3-Nitroaniline (99-09-2)
4-Nitroaniline (100-01-6)
Nitrobenzene (98-95-3)
2-Nitrophenol (88-75-5)
4-Nitrophenol (100-02-7)
N-Nitrosodimethylamine (62-75-9)
N-Nitroso-di-n-propylamine (621-64-7)
2,2'-Oxybis(1-chloropropane) (108-60-1)
Pentachlorophenol (87-86-5)
Phenanthrene (85-01-8)
Phenol (108-95-2)
Pyrene (129-00-0)
Pyridine (110-86-1)
2,3,4,6-Tetrachlorophenol (58-90-2)
2,3,5,6-Tetrachlorophenol (935-95-5)
1,2,4-Trichlorobenzene (120-82-1)
2,4,5-Trichlorophenol (95-95-4)
2,4,6-Trichlorophenol (88-06-2)
31834: 605 Benzidines Calibration Mix
Benzidine (92-87-5)
3,3'-Dichlorobenzidine (91-94-1)
32459: Appendix IX Mix #1, Revised (Note: methapyrilene is not included in this revised standard.)
2-Acetylaminofluorene (53-96-3)
4-Aminobiphenyl (92-67-1)
p-Dimethylaminoazobenzene (60-11-7)
3,3'-Dimethylbenzidine (o-tolidine) (119-93-7)
α,α-Dimethylphenethylamine (phentermine) (122-09-8)
1-Naphthylamine (1-aminonaphthalene) (134-32-7)
2-Naphthylamine (2-aminonaphthalene) (91-59-8)
N-Nitrosodibutylamine (924-16-3)
N-Nitrosodiethylamine (55-18-5)
N-Nitrosomethylethylamine (10595-95-6)
N-Nitrosomorpholine (59-89-2)
N-Nitrosopiperidine (100-75-4)
N-Nitrosopyrrolidine (930-55-2)
5-Nitro-o-toluidine (99-55-8)
1,4-Phenylenediamine (106-50-3)
2-Picoline (109-06-8)
o-Toluidine (95-53-4)
32460: Methapyrilene Standard
Methapyrilene hydrochloride (135-23-9)
31806: Appendix IX Mix #2
Acetophenone (98-86-2)
Aramite (140-57-8)
Atrazine (1912-24-9)
Benzaldehyde (100-52-7)
Biphenyl (92-52-4)
ε-Caprolactam (105-60-2)
Chlorobenzilate (510-15-6)
1-Chloronaphthalene (90-13-1)
Diallate (2303-16-4)
Dibenz[a,j]acridine (224-42-0)
2,6-Dichlorophenol (87-65-0)
7,12-Dimethylbenz[a]anthracene (57-97-6)
1,4-Dioxane (123-91-1)
Diphenyl ether (101-84-8)
Ethyl methacrylate (97-63-2)
Ethyl methanesulfonate (62-50-0)
Hexachloropropene (1888-71-7)
Isodrin (465-73-6)
Isosafrole (cis & trans) (120-58-1)
Kepone (143-50-0)
3-Methylcholanthrene (56-49-5)
Methyl methanesulfonate (66-27-3)
1,4-Naphthoquinone (130-15-4)
4-Nitroquinoline-N-oxide (56-57-5)
Pentachlorobenzene (608-93-5)
Pentachloroethane (76-01-7)
Pentachloronitrobenzene (Quintozene) (82-68-8)
Phenacetin (62-44-2)
Propyzamide (23950-58-5)
Safrole (94-59-7)
1,2,4,5-Tetrachlorobenzene (95-94-3)
1,3,5-Trinitrobenzene (99-35-4)
*1,2-diphenylhydrazine (8270-listed analyte) decomposes to azobenzene (mix component) in the injector.
†N-ニトロソジフェニルアミンは、混合物中の他の化合物の早期分解を招く可能性がある反応性種であるため、この混合物の調製にはジフェニルアミンが使用されます。