![Restek](/file/general/restek-logo.png)
![Restek](/file/general/restek-logo.png)
![8270 MegaMix Standard, 1000 µg/mL, Methylene Chloride, 1 mL/ampul 8270 MegaMix Standard, 1000 µg/mL, Methylene Chloride, 1 mL/ampul](/ccstore/v1/images/?source=/file/v7839387720295474101/products/ampul-0to2ml_ph_so_arm.jpg&height=475&width=475&quality=0.8&outputFormat=JPEG)
8270 MegaMix Standard, 1000 µg/mL, Methylene Chloride, 1 mL/ampul
![8270 MegaMix Standard, 1000 µg/mL, Methylene Chloride, 1 mL/ampul](/ccstore/v1/images/?source=/file/v7839387720295474101/products/ampul-0to2ml_ph_so_arm.jpg&height=200&width=200)
8270 MegaMix Standard, 1000 µg/mL, Methylene Chloride, 1 mL/ampul
概要
- Fewest mixtures needed for calibration and matrix spikes.
- Mixtures formulated for maximum stability.
- Contains most routinely analyzed compounds.
Simplify calibration with SVOC MegaMix reference standards kits that contain 150 (cat.# 31907) or 100 (cat.# 31908) of the most frequently analyzed semivolatiles.
Acenaphthene (83-32-9)
Acenaphthylene (208-96-8)
Aniline (62-53-3)
Anthracene (120-12-7)
Azobenzene (103-33-3)*
Benz[a]anthracene (56-55-3)
Benzo[a]pyrene (50-32-8)
Benzo[b]fluoranthene (205-99-2)
Benzo[g,h,i]perylene (191-24-2)
Benzo[k]fluoranthene (207-08-9)
Benzyl alcohol (100-51-6)
Benzyl butyl phthalate (85-68-7)
Bis(2-chloroethoxy)methane (111-91-1)
Bis(2-chloroethyl)ether (111-44-4)
Bis(2-ethylhexyl)adipate (103-23-1)
Bis(2-ethylhexyl)phthalate (117-81-7)
4-Bromophenyl phenyl ether (101-55-3)
Carbazole (86-74-8)
4-Chloroaniline (106-47-8)
4-Chloro-3-methylphenol (59-50-7)
2-Chloronaphthalene (91-58-7)
2-Chlorophenol (95-57-8)
4-Chlorophenyl phenyl ether (7005-72-3)
Chrysene (218-01-9)
Dibenz[a,h]anthracene (53-70-3)
Dibenzofuran (132-64-9)
1,2-Dichlorobenzene (95-50-1)
1,3-Dichlorobenzene (541-73-1)
1,4-Dichlorobenzene (106-46-7)
2,4-Dichlorophenol (120-83-2)
Diethylphthalate (84-66-2)
2,4-Dimethylphenol (105-67-9)
Dimethylphthalate (131-11-3)
Di-n-butyl phthalate (84-74-2)
1,2-Dinitrobenzene (528-29-0)
1,3-Dinitrobenzene (99-65-0)
1,4-Dinitrobenzene (100-25-4)
4,6-Dinitro-2-methylphenol (Dinitro-o-cresol) (534-52-1)
2,4-Dinitrophenol (51-28-5)
2,4-Dinitrotoluene (121-14-2)
2,6-Dinitrotoluene (606-20-2)
Di-n-octyl phthalate (117-84-0)
Diphenylamine (122-39-4)†
Fluoranthene (206-44-0)
Fluorene (86-73-7)
Hexachlorobenzene (118-74-1)
Hexachlorobutadiene (87-68-3)
Hexachlorocyclopentadiene (77-47-4)
Hexachloroethane (67-72-1)
Indeno[1,2,3-cd]pyrene (193-39-5)
Isophorone (78-59-1)
1-Methylnaphthalene (90-12-0)
2-Methylnaphthalene (91-57-6)
2-Methylphenol (o-cresol) (95-48-7)
3-Methylphenol (m-cresol) (108-39-4)
4-Methylphenol (p-cresol) (106-44-5)
Naphthalene (91-20-3)
2-Nitroaniline (88-74-4)
3-Nitroaniline (99-09-2)
4-Nitroaniline (100-01-6)
Nitrobenzene (98-95-3)
2-Nitrophenol (88-75-5)
4-Nitrophenol (100-02-7)
N-Nitrosodimethylamine (62-75-9)
N-Nitroso-di-n-propylamine (621-64-7)
2,2'-Oxybis(1-chloropropane) (108-60-1)
Pentachlorophenol (87-86-5)
Phenanthrene (85-01-8)
Phenol (108-95-2)
Pyrene (129-00-0)
Pyridine (110-86-1)
2,3,4,6-Tetrachlorophenol (58-90-2)
2,3,5,6-Tetrachlorophenol (935-95-5)
1,2,4-Trichlorobenzene (120-82-1)
2,4,5-Trichlorophenol (95-95-4)
2,4,6-Trichlorophenol (88-06-2)
*1,2-diphenylhydrazine (8270-listed analyte) decomposes to azobenzene (mix component) in the injector.
†N-ニトロソジフェニルアミンは、混合物中の他の化合物の早期分解を招く可能性がある反応性種であるため、この混合物の調製にはジフェニルアミンが使用されます。