![Restek](/file/general/restek-logo.png)
![Restek](/file/general/restek-logo.png)
![SVOC MegaMix 150 Kit, 1 mL/ampul; 6 ampuls/kit SVOC MegaMix 150 Kit, 1 mL/ampul; 6 ampuls/kit](/ccstore/v1/images/?source=/file/v7839387720295474101/products/ampul-0to2ml_ph_so_arm.jpg&height=475&width=475&quality=0.8&outputFormat=JPEG)
SVOC MegaMix 150 Kit, 1 mL/ampul; 6 ampuls/kit
![SVOC MegaMix 150 Kit, 1 mL/ampul; 6 ampuls/kit](/ccstore/v1/images/?source=/file/v7839387720295474101/products/ampul-0to2ml_ph_so_arm.jpg&height=200&width=200)
SVOC MegaMix 150 Kit, 1 mL/ampul; 6 ampuls/kit
概要
- Streamline operations: kit contains 150 of the most frequently analyzed semivolatiles.
- Designed to make it easy to construct a 200 µg/mL working standard, allowing for wider calibration ranges, and reducing the need for sample dilution.
- Formulated for greater stability to ensure more accurate data.
- Available in two independently manufactured lots with verified lot-to-lot agreement, reducing uncertainty and improving quality.
U.S. DEA-exempted formulation—no additional customer permits or licensing are required to purchase within the U.S.
Also available: SVOC MegaMix 100 kit (cat.# 31908) contains 100 of the most frequently analyzed semivolatiles (does not contain Appendix IX mixes or methapyrilene).
このキットには、以下のものが各1アンプル入っています。
Cat.# 31850: 8270 MegaMix1000 µg/mL each in methylene chloride (3-methylphenol and 4-methylphenol at 500 µg/mL), 1 mL/ampul
Acenaphthene (83-32-9)
Acenaphthylene (208-96-8)
Aniline (62-53-3)
Anthracene (120-12-7)
Azobenzene (103-33-3)*
Benz[a]anthracene (56-55-3)
Benzo[a]pyrene (50-32-8)
Benzo[b]fluoranthene (205-99-2)
Benzo[g,h,i]perylene (191-24-2)
Benzo[k]fluoranthene (207-08-9)
Benzyl alcohol (100-51-6)
Benzyl butyl phthalate (85-68-7)
Bis(2-chloroethoxy)methane (111-91-1)
Bis(2-chloroethyl)ether (111-44-4)
Bis(2-ethylhexyl)adipate (103-23-1)
Bis(2-ethylhexyl)phthalate (117-81-7)
4-Bromophenyl phenyl ether (101-55-3)
Carbazole (86-74-8)
4-Chloroaniline (106-47-8)
4-Chloro-3-methylphenol (59-50-7)
2-Chloronaphthalene (91-58-7)
2-Chlorophenol (95-57-8)
4-Chlorophenyl phenyl ether (7005-72-3)
Chrysene (218-01-9)
Dibenz[a,h]anthracene (53-70-3)
Dibenzofuran (132-64-9)
1,2-Dichlorobenzene (95-50-1)
1,3-Dichlorobenzene (541-73-1)
1,4-Dichlorobenzene (106-46-7)
2,4-Dichlorophenol (120-83-2)
Diethylphthalate (84-66-2)
2,4-Dimethylphenol (105-67-9)
Dimethylphthalate (131-11-3)
Di-n-butyl phthalate (84-74-2)
1,2-Dinitrobenzene (528-29-0)
1,3-Dinitrobenzene (99-65-0)
1,4-Dinitrobenzene (100-25-4)
4,6-Dinitro-2-methylphenol (Dinitro-o-cresol) (534-52-1)
2,4-Dinitrophenol (51-28-5)
2,4-Dinitrotoluene (121-14-2)
2,6-Dinitrotoluene (606-20-2)
Di-n-octyl phthalate (117-84-0)
Diphenylamine (122-39-4)†
Fluoranthene (206-44-0)
Fluorene (86-73-7)
Hexachlorobenzene (118-74-1)
Hexachlorobutadiene (87-68-3)
Hexachlorocyclopentadiene (77-47-4)
Hexachloroethane (67-72-1)
Indeno[1,2,3-cd]pyrene (193-39-5)
Isophorone (78-59-1)
1-Methylnaphthalene (90-12-0)
2-Methylnaphthalene (91-57-6)
2-Methylphenol (o-cresol) (95-48-7)
3-Methylphenol (m-cresol) (108-39-4)
4-Methylphenol (p-cresol) (106-44-5)
Naphthalene (91-20-3)
2-Nitroaniline (88-74-4)
3-Nitroaniline (99-09-2)
4-Nitroaniline (100-01-6)
Nitrobenzene (98-95-3)
2-Nitrophenol (88-75-5)
4-Nitrophenol (100-02-7)
N-Nitrosodimethylamine (62-75-9)
N-Nitroso-di-n-propylamine (621-64-7)
2,2'-Oxybis(1-chloropropane) (108-60-1)
Pentachlorophenol (87-86-5)
Phenanthrene (85-01-8)
Phenol (108-95-2)
Pyrene (129-00-0)
Pyridine (110-86-1)
2,3,4,6-Tetrachlorophenol (58-90-2)
2,3,5,6-Tetrachlorophenol (935-95-5)
1,2,4-Trichlorobenzene (120-82-1)
2,4,5-Trichlorophenol (95-95-4)
2,4,6-Trichlorophenol (88-06-2)
Cat.# 31909: SVOC Additions
1000 µg/mL each in methylene chloride, 1 mL/ampul
Acrylamide (79-06-1)
Benzidine (92-87-5)
n-Decane (C10) (124-18-5)
Dibenz(a,h)acridine (226-36-8)
2,3-Dichloroaniline (608-27-5)
3,3'-Dichlorobenzidine (91-94-1)
Dimethoate (60-51-5)
Dinoseb (88-85-7)
Disulfoton (298-04-4)
Famphur (52-85-7)
n-Hexadecane (C16) (544-76-3)
Indene (95-13-6)
Methyl parathion (298-00-0)
6-Methylchrysene (1705-85-7)
4,4'-Methylene-bis(2-chloroaniline) (101-14-4)
n-Octadecane (C18) (593-45-3)
Parathion (ethyl parathion) (56-38-2)
Phorate (298-02-2)
Quinoline (91-22-5)
Sulfotepp (3689-24-5)
α-Terpineol (98-55-5)
o,o,o-Triethyl phosphorothioate (126-68-1)
Zalophus (thionazine) (297-97-2)
Cat.# 32459: Appendix IX mix #1, revised
2000 µg/mL each in methylene chloride, 1 mL/ampul
2-Acetylaminofluorene (53-96-3)
4-Aminobiphenyl (92-67-1)
p-Dimethylaminoazobenzene (60-11-7)
3,3'-Dimethylbenzidine (o-tolidine) (119-93-7)
α,α-Dimethylphenethylamine (phentermine) (122-09-8)
1-Naphthylamine (1-aminonaphthalene) (134-32-7)
2-Naphthylamine (2-aminonaphthalene) (91-59-8)
N-Nitrosodibutylamine (924-16-3)
N-Nitrosodiethylamine (55-18-5)
N-Nitrosomethylethylamine (10595-95-6)
N-Nitrosomorpholine (59-89-2)
N-Nitrosopiperidine (100-75-4)
N-Nitrosopyrrolidine (930-55-2)
5-Nitro-o-toluidine (99-55-8)
1,4-Phenylenediamine (106-50-3)
2-Picoline (109-06-8)
o-Toluidine (95-53-4)
Cat.# 32460: Methapyrilene
2000 µg/mL in methylene chloride, 1 mL/ampul
Methapyrilene hydrochloride (135-23-9)
Cat.# 31806: Appendix IX mix #2
1000 µg/mL each in methylene chloride, 1 mL/ampul
Acetophenone (98-86-2)
Aramite (140-57-8)
Atrazine (1912-24-9)
Benzaldehyde (100-52-7)
Biphenyl (92-52-4)
ε-Caprolactam (105-60-2)
Chlorobenzilate (510-15-6)
1-Chloronaphthalene (90-13-1)
Diallate (2303-16-4)
Dibenz[a,j]acridine (224-42-0)
2,6-Dichlorophenol (87-65-0)
7,12-Dimethylbenz[a]anthracene (57-97-6)
1,4-Dioxane (123-91-1)
Diphenyl ether (101-84-8)
Ethyl methacrylate (97-63-2)
Ethyl methanesulfonate (62-50-0)
Hexachloropropene (1888-71-7)
Isodrin (465-73-6)
Isosafrole (cis & trans) (120-58-1)
Kepone (143-50-0)
3-Methylcholanthrene (56-49-5)
Methyl methanesulfonate (66-27-3)
1,4-Naphthoquinone (130-15-4)
4-Nitroquinoline-N-oxide (56-57-5)
Pentachlorobenzene (608-93-5)
Pentachloroethane (76-01-7)
Pentachloronitrobenzene (Quintozene) (82-68-8)
Phenacetin (62-44-2)
Propyzamide (23950-58-5)
Safrole (94-59-7)
1,2,4,5-Tetrachlorobenzene (95-94-3)
1,3,5-Trinitrobenzene (99-35-4)
Cat.# 31879: Benzoic acid
2000 µg/mL in methylene chloride, 1 mL/ampul
Benzoic acid (65-85-0)
*1,2-diphenylhydrazine (8270-listed analyte) decomposes to azobenzene (mix component) in the injector.
†N-ニトロソジフェニルアミンは、混合物中の他の化合物の早期分解を招く可能性がある反応性種であるため、この混合物の調製にはジフェニルアミンが使用されます。