![Restek](/file/general/restek-logo.png)
![Restek](/file/general/restek-logo.png)
![SVOC MegaMix 100 Kit: 1 mL/ampul; 3 ampuls/kit SVOC MegaMix 100 Kit: 1 mL/ampul; 3 ampuls/kit](/ccstore/v1/images/?source=/file/v7839387720295474101/products/ampul-0to2ml_ph_so_arm.jpg&height=475&width=475&quality=0.8&outputFormat=JPEG)
SVOC MegaMix 100 Kit: 1 mL/ampul; 3 ampuls/kit
![SVOC MegaMix 100 Kit: 1 mL/ampul; 3 ampuls/kit](/ccstore/v1/images/?source=/file/v7839387720295474101/products/ampul-0to2ml_ph_so_arm.jpg&height=200&width=200)
SVOC MegaMix 100 Kit: 1 mL/ampul; 3 ampuls/kit
概要
- Streamline operations: kit contains 100 of the most frequently analyzed semivolatiles.
- Designed to make it easy to construct a 200 µg/mL working standard, allowing for wider calibration ranges, and reducing the need for sample dilution.
- Formulated for greater stability to ensure more accurate data.
- Available in two independently manufactured lots with verified lot-to-lot agreement, reducing uncertainty and improving quality.
Also available: SVOC MegaMix 150 kit (cat.# 31907) contains 150 of the most frequently analyzed semivolatiles.
このキットには、以下のものが各1アンプル入っています。
Cat.# 31850: 8270 MegaMix1000 µg/mL each in methylene chloride (3-methylphenol and 4-methylphenol at 500 µg/mL), 1 mL/ampul
Acenaphthene (83-32-9)
Acenaphthylene (208-96-8)
Aniline (62-53-3)
Anthracene (120-12-7)
Azobenzene (103-33-3)*
Benz[a]anthracene (56-55-3)
Benzo[a]pyrene (50-32-8)
Benzo[b]fluoranthene (205-99-2)
Benzo[g,h,i]perylene (191-24-2)
Benzo[k]fluoranthene (207-08-9)
Benzyl alcohol (100-51-6)
Benzyl butyl phthalate (85-68-7)
Bis(2-chloroethoxy)methane (111-91-1)
Bis(2-chloroethyl)ether (111-44-4)
Bis(2-ethylhexyl)adipate (103-23-1)
Bis(2-ethylhexyl)phthalate (117-81-7)
4-Bromophenyl phenyl ether (101-55-3)
Carbazole (86-74-8)
4-Chloroaniline (106-47-8)
4-Chloro-3-methylphenol (59-50-7)
2-Chloronaphthalene (91-58-7)
2-Chlorophenol (95-57-8)
4-Chlorophenyl phenyl ether (7005-72-3)
Chrysene (218-01-9)
Dibenz[a,h]anthracene (53-70-3)
Dibenzofuran (132-64-9)
1,2-Dichlorobenzene (95-50-1)
1,3-Dichlorobenzene (541-73-1)
1,4-Dichlorobenzene (106-46-7)
2,4-Dichlorophenol (120-83-2)
Diethylphthalate (84-66-2)
2,4-Dimethylphenol (105-67-9)
Dimethylphthalate (131-11-3)
Di-n-butyl phthalate (84-74-2)
1,2-Dinitrobenzene (528-29-0)
1,3-Dinitrobenzene (99-65-0)
1,4-Dinitrobenzene (100-25-4)
4,6-Dinitro-2-methylphenol (Dinitro-o-cresol) (534-52-1)
2,4-Dinitrophenol (51-28-5)
2,4-Dinitrotoluene (121-14-2)
2,6-Dinitrotoluene (606-20-2)
Di-n-octyl phthalate (117-84-0)
Diphenylamine (122-39-4)†
Fluoranthene (206-44-0)
Fluorene (86-73-7)
Hexachlorobenzene (118-74-1)
Hexachlorobutadiene (87-68-3)
Hexachlorocyclopentadiene (77-47-4)
Hexachloroethane (67-72-1)
Indeno[1,2,3-cd]pyrene (193-39-5)
Isophorone (78-59-1)
1-Methylnaphthalene (90-12-0)
2-Methylnaphthalene (91-57-6)
2-Methylphenol (o-cresol) (95-48-7)
3-Methylphenol (m-cresol) (108-39-4)
4-Methylphenol (p-cresol) (106-44-5)
Naphthalene (91-20-3)
2-Nitroaniline (88-74-4)
3-Nitroaniline (99-09-2)
4-Nitroaniline (100-01-6)
Nitrobenzene (98-95-3)
2-Nitrophenol (88-75-5)
4-Nitrophenol (100-02-7)
N-Nitrosodimethylamine (62-75-9)
N-Nitroso-di-n-propylamine (621-64-7)
2,2'-Oxybis(1-chloropropane) (108-60-1)
Pentachlorophenol (87-86-5)
Phenanthrene (85-01-8)
Phenol (108-95-2)
Pyrene (129-00-0)
Pyridine (110-86-1)
2,3,4,6-Tetrachlorophenol (58-90-2)
2,3,5,6-Tetrachlorophenol (935-95-5)
1,2,4-Trichlorobenzene (120-82-1)
2,4,5-Trichlorophenol (95-95-4)
2,4,6-Trichlorophenol (88-06-2)
Cat.# 31909: SVOC Additions
1000 µg/mL each in methylene chloride, 1 mL/ampul
Acrylamide (79-06-1)
Benzidine (92-87-5)
n-Decane (C10) (124-18-5)
Dibenz(a,h)acridine (226-36-8)
2,3-Dichloroaniline (608-27-5)
3,3'-Dichlorobenzidine (91-94-1)
Dimethoate (60-51-5)
Dinoseb (88-85-7)
Disulfoton (298-04-4)
Famphur (52-85-7)
n-Hexadecane (C16) (544-76-3)
Indene (95-13-6)
Methyl parathion (298-00-0)
6-Methylchrysene (1705-85-7)
4,4'-Methylene-bis(2-chloroaniline) (101-14-4)
n-Octadecane (C18) (593-45-3)
Parathion (ethyl parathion) (56-38-2)
Phorate (298-02-2)
Quinoline (91-22-5)
Sulfotepp (3689-24-5)
α-Terpineol (98-55-5)
o,o,o-Triethyl phosphorothioate (126-68-1)
Zalophus (thionazine) (297-97-2)
Cat.# 31879: Benzoic acid
2000 µg/mL in methylene chloride, 1 mL/ampul
Benzoic acid (65-85-0)
*1,2-diphenylhydrazine (8270-listed analyte) decomposes to azobenzene (mix component) in the injector.
†N-ニトロソジフェニルアミンは、混合物中の他の化合物の早期分解を招く可能性がある反応性種であるため、この混合物の調製にはジフェニルアミンが使用されます。