ホーム / Reference Standards / 混合品 / Arizona Pesticide Kit, 1 mL/ampul, 4 ampuls/kit
Restek
Arizona Pesticide Kit, 1 mL/ampul, 4 ampuls/kit
  1. Arizona Pesticide Kit, 1 mL/ampul, 4 ampuls/kit

Arizona Pesticide Kit, 1 mL/ampul, 4 ampuls/kit

カタログ番号 32600
Arizona Pesticide Kit, 1 mL/ampul, 4 ampuls/kit

Arizona Pesticide Kit, 1 mL/ampul, 4 ampuls/kit

概要

特徴&利点
  • 58-component kit provides analytical flexibility for constructing calibration curves or spiking sample matrices—saving time and reducing cost.
  • The standard concentration of each mix is 400 times the action limit—100 times when all four mixes are combined.
  • Two independently produced lots available.
  • Verified composition and stability ensures long-lasting shelf life.
  • Formulated for Arizona cannabis regulations; can be used to meet other government or in-house method requirements.
製品詳細

このキットには、以下のものが各1アンプル入っています。 1 mL/ampul

 

Cat.# 32601: Arizona Pesticide Standard #1

化合物 CAS# Concentration
Acephate 30560-19-1 160 µg/mL
Aldicarb 116-06-3 160 µg/mL
Bifenazate 149877-41-8 80 µg/mL
Carbaryl (Sevin) 63-25-2 80 µg/mL
Carbofuran 1563-66-2 80 µg/mL
Chlorpyrifos 2921-88-2 80 µg/mL
Dichlorvos 62-73-7 40 µg/mL
Diazinon 333-41-5 80 µg/mL
Dimethoate 60-51-5 80 µg/mL
Ethoprophos 13194-48-4 80 µg/mL
Fenoxycarb 72490-01-8 80 µg/mL
Malathion 121-75-5 80 µg/mL
Methiocarb 2032-65-7 80 µg/mL
Methomyl 16752-77-5 160 µg/mL
Naled 300-76-5 200 µg/mL
Oxamyl 23135-22-0 400 µg/mL
Phosmet 732-11-6 80 µg/mL
Propoxur 114-26-1 80 µg/mL

 

Cat.# 32602: Arizona Pesticide Standard #2

化合物 CAS# Concentration
Abamectin 71751-41-2 200 µg/mL
Acequinocyl 57960-19-7 800 µg/mL
Bifenthrin 82657-04-3 80 µg/mL
Cyfluthrin 68359-37-5 400 µg/mL
Cypermethrin 52315-07-8 400 µg/mL
Etofenprox 80844-07-1 160 µg/mL
Permethrin (cis & trans) 52645-53-1 80 µg/mL
Prallethrin 23031-36-9 80 µg/mL
Pyrethrins* 8003-34-7 400 µg/mL
Spinosad (A&D) 168316-95-8 80 µg/mL

 

Cat.# 32603: Arizona Pesticide Standard #3

化合物 CAS# Concentration
Acetamiprid 135410-20-7 80 µg/mL
Clofentezine 74115-24-5 80 µg/mL
Etoxazole 153233-91-1 80 µg/mL
Fipronil 120068-37-3 160 µg/mL
Fludioxonil 131341-86-1 160 µg/mL
Imazalil 35554-44-0 80 µg/mL
Imidacloprid 138261-41-3 160 µg/mL
Myclobutanil 88671-89-0 80 µg/mL
Paclobutrazol 76738-62-0 160 µg/mL
Pendimethalin 40487-42-1 40 µg/mL
Propiconazole (Tilt) 60207-90-1 160 µg/mL
Tebuconazole 107534-96-3 160 µg/mL
Thiacloprid 111988-49-9 80 µg/mL
Thiamethoxam 153719-23-4 80 µg/mL

 

Cat.# 32604: Arizona Pesticide Standard #4

化合物 CAS# Concentration
Azoxystrobin 131860-33-8 80 µg/mL
Boscalid 188425-85-6 160 µg/mL
Chlorantraniliprole 500008-45-7 80 µg/mL
Chlorfenapyr 122453-73-0 400 µg/mL
Daminozide 1596-84-5 400 µg/mL
(E)-Fenpyroximate 134098-61-6 160 µg/mL
Flonicamid 158062-67-0 400 µg/mL
Hexythiazox 78587-05-0 400 µg/mL
Kresoxim methyl 143390-89-0 160 µg/mL
Metalaxyl 57837-19-1 80 µg/mL
Piperonyl butoxide 51-03-6 800 µg/mL
Pyridaben 96489-71-3 80 µg/mL
Spiromesifen 283594-90-1 80 µg/mL
Spirotetramat 203313-25-1 80 µg/mL
Spiroxamine 118134-30-8 160 µg/mL
Trifloxystrobin 141517-21-7 80 µg/mL

 

*Pyrethrinsは、6 つの活性殺虫性化合物よりなるTechnical Mixtureとなります。各化合物の比率は、証明書に記載された分析条件での溶出順に応じて記載されており、クロマトグラム上ではもっとも信号強度が高いPyrethrin化合物のピークだけがラベル付けされています。Pyrethrinsの性質により、原料に依存してロット間での組成と純度のばらつきが観察されることがあります。

This reference material contains スピノサド A and D isomers (131929-60-7 and 131929-63-0); however, CAS# 168316-95-8 is displayed on the certificate as this is the neat material dissolved in the solution. CAS# 168316-95-8 is a blend of スピノサド A and D, and the ratio of each material isomer are displayed on your certificate of analysis.

クロルアントラニリプロール (500008-45-7) およびダミノジット (1596-84-5) を含む標準物質は、アンプル開封前に最低60分の超音波処理を行ってください。60分は目安となります。超音波処理時間の延長は製品品質に影響しませんので、ご使用の超音波バスの出力レベルに応じて、処理時間の調整を行ってください。この処理は、製品だけでなく、ラボで調整された同成分のWorking Solutionにも適用されます。沈殿する化合物の量は濃度と温度によって異なりますが、標準液の希釈溶液であっても、ラベル記載の推奨温度を大きく下回る温度で保存する場合は、低温による化合物溶解度の低下が懸念されるため、通常よりも長い超音波処理時間を設定することをお勧めします。

仕様

製品仕様
カタログ番号
32600
製品名
Arizona Pesticide Kit, 1 mL/ampul, 4 ampuls/kit
Can't find what you're looking for?
カスタムリファレンススタンダード

リファレンススタンダードのカスタム品に関するご相談も承っております。カスタム品のご依頼はこちらのフォームをご利用ください。