![Restek](/file/general/restek-logo.png)
Home / Gas Chromatography / Gas Purification & Generators / Gas Generators / Parker Zero Air Generator, HPZA-3500 Model, 3500 cc/min Capacity
![Restek](/file/general/restek-logo.png)
![Parker Zero Air Generator, HPZA-3500 Model, 3500 cc/min Capacity Parker Zero Air Generator, HPZA-3500 Model, 3500 cc/min Capacity](/ccstore/v1/images/?source=/file/v5723012306696595085/products/grp-parker-zero-air-hpza-generators.jpg&height=475&width=475&quality=0.8&outputFormat=JPEG)
Parker Zero Air Generator, HPZA-3500 Model, 3500 cc/min Capacity
Catalog No. 20680
Ordering Note
International power cords are available. Contact Customer Service to order.
![Parker Zero Air Generator, HPZA-3500 Model, 3500 cc/min Capacity](/ccstore/v1/images/?source=/file/v5723012306696595085/products/grp-parker-zero-air-hpza-generators.jpg&height=200&width=200)
Parker Zero Air Generator, HPZA-3500 Model, 3500 cc/min Capacity
Overview
Features & Benefits
- Turn in-house compressed air into ultra-pure air.
- Remove hydrocarbons to less than 0.1 ppm by catalytic oxidation.
- Operate at 40–125 psi (276–862 kPa).
- Typical payback is less than one year, based on cylinder costs.
- Installs easily and takes up little bench space.
- Maintenance kits include a one-year supply of prefilters and final filter.
Description
Specifications for Parker Balston Zero Air Generators
Maximum Zero Air Flow Rate: | 75-83NA HPZA-3500 HPZA-7000 HPZA-18000 HPZA-30000 |
1.0 L/min 3.5 L/min 7.0 L/min 18 L/min 30 L/min |
Outlet Hydrocarbon Concentration (as methane): | 75-83NA HPZA-30000 Other Models |
< 0.1 ppm < 0.1 ppm < 0.05 ppm |
Minimum/Maximum Inlet Air Pressure: | 40 psig/125 psig (276/862 kPa) | |
Maximum Inlet Hydrocarbon Concentration (as methane): | 100 ppm | |
Pressure Drop at Maximum Flow Rate: | 4 psi (28 kPa) differential | |
Maximum Inlet Air Temperature: | 78°F (25°C) | |
Inlet/Outlet Ports: | 1/4" NPT (female) | |
Start-up Time to Specified Hydrocarbon Concentration: | 45 minutes | |
Electrical Requirements: | 75-83NA HPZA-3500, HPZA-7000 HPZA-18000, HPZA-30000 |
120 VAC/60 Hz, 0.5 amps 120, 220, 230, 240 VAC/60 Hz, 2.0 amps 120, 220, 230, 240 VAC/60 Hz, 4.0 amps |
Dimensions: | 75-83NA Other Models |
10" h x 12" w x 3" d (25 cm x 30 cm x 8 cm) 16" h x 11" w x 13" d (42 cm x 27 cm x 34 cm) |
Shipping Weight: | 75-83NA Other Models |
7 lb (3 kg) 41 lb (19 kg) |
Model | Number of FIDs (based on a 450 cc/min fuel air rate) |
75-83NA | Up to 2 |
HPZA-3500 | Up to 8 |
HPZA-7000 | Up to 16 |
HPZA-18000 | Up to 40 |
HPZA-30000 | Up to 66 |
Specifications
Product Specifications
Catalog No.
20680
Product Name
Parker Zero Air Generator, HPZA-3500 Model, 3500 cc/min Capacity