8270/Appendix IX Kit
  1. 8270/Appendix IX Kit

8270/Appendix IX Kit

Catalog No. 31815
8270/Appendix IX Kit

8270/Appendix IX Kit

Overview

Features & Benefits

U.S. DEA-exempted formulation—no additional customer permits or licensing are required to purchase within the U.S.

Simplify calibration with SVOC MegaMix reference standards kits that contain 150 (cat.# 31907) or 100 (cat.# 31908) of the most frequently analyzed semivolatiles.

Description

Contains 1 mL each of these mixtures.

31850: 8270 MegaMix Standard
Acenaphthene (83-32-9)
Acenaphthylene (208-96-8)
Aniline (62-53-3)
Anthracene (120-12-7)
Azobenzene (103-33-3)*
Benz[a]anthracene (56-55-3)
Benzo[a]pyrene (50-32-8)
Benzo[b]fluoranthene (205-99-2)
Benzo[g,h,i]perylene (191-24-2)
Benzo[k]fluoranthene (207-08-9)
Benzyl alcohol (100-51-6)
Benzyl butyl phthalate (85-68-7)
Bis(2-chloroethoxy)methane (111-91-1)
Bis(2-chloroethyl)ether (111-44-4)
Bis(2-ethylhexyl)adipate (103-23-1)
Bis(2-ethylhexyl)phthalate (117-81-7)
4-Bromophenyl phenyl ether (101-55-3)
Carbazole (86-74-8)
4-Chloroaniline (106-47-8)
4-Chloro-3-methylphenol (59-50-7)
2-Chloronaphthalene (91-58-7)
2-Chlorophenol (95-57-8)
4-Chlorophenyl phenyl ether (7005-72-3)
Chrysene (218-01-9)
Dibenz[a,h]anthracene (53-70-3)
Dibenzofuran (132-64-9)
1,2-Dichlorobenzene (95-50-1)
1,3-Dichlorobenzene (541-73-1)
1,4-Dichlorobenzene (106-46-7)
2,4-Dichlorophenol (120-83-2)
Diethylphthalate (84-66-2)
2,4-Dimethylphenol (105-67-9)
Dimethylphthalate (131-11-3)
Di-n-butyl phthalate (84-74-2)
1,2-Dinitrobenzene (528-29-0)
1,3-Dinitrobenzene (99-65-0)
1,4-Dinitrobenzene (100-25-4)
4,6-Dinitro-2-methylphenol (Dinitro-o-cresol) (534-52-1)
2,4-Dinitrophenol (51-28-5)
2,4-Dinitrotoluene (121-14-2)
2,6-Dinitrotoluene (606-20-2)
Di-n-octyl phthalate (117-84-0)
Diphenylamine (122-39-4)
Fluoranthene (206-44-0)
Fluorene (86-73-7)
Hexachlorobenzene (118-74-1)
Hexachlorobutadiene (87-68-3)
Hexachlorocyclopentadiene (77-47-4)
Hexachloroethane (67-72-1)
Indeno[1,2,3-cd]pyrene (193-39-5)
Isophorone (78-59-1)
1-Methylnaphthalene (90-12-0)
2-Methylnaphthalene (91-57-6)
2-Methylphenol (o-cresol) (95-48-7)
3-Methylphenol (m-cresol) (108-39-4)
4-Methylphenol (p-cresol) (106-44-5)
Naphthalene (91-20-3)
2-Nitroaniline (88-74-4)
3-Nitroaniline (99-09-2)
4-Nitroaniline (100-01-6)
Nitrobenzene (98-95-3)
2-Nitrophenol (88-75-5)
4-Nitrophenol (100-02-7)
N-Nitrosodimethylamine (62-75-9)
N-Nitroso-di-n-propylamine (621-64-7)
2,2'-Oxybis(1-chloropropane) (108-60-1)
Pentachlorophenol (87-86-5)
Phenanthrene (85-01-8)
Phenol (108-95-2)
Pyrene (129-00-0)
Pyridine (110-86-1)
2,3,4,6-Tetrachlorophenol (58-90-2)
2,3,5,6-Tetrachlorophenol (935-95-5)
1,2,4-Trichlorobenzene (120-82-1)
2,4,5-Trichlorophenol (95-95-4)
2,4,6-Trichlorophenol (88-06-2)

31834: 605 Benzidines Calibration Mix
Benzidine (92-87-5)
3,3'-Dichlorobenzidine (91-94-1)

32459: Appendix IX Mix #1, Revised (Note: methapyrilene is not included in this revised standard.)
2-Acetylaminofluorene (53-96-3)
4-Aminobiphenyl (92-67-1)
p-Dimethylaminoazobenzene (60-11-7)
3,3'-Dimethylbenzidine (o-tolidine) (119-93-7)
α,α-Dimethylphenethylamine (phentermine) (122-09-8)
1-Naphthylamine (1-aminonaphthalene) (134-32-7)
2-Naphthylamine (2-aminonaphthalene) (91-59-8)
N-Nitrosodibutylamine (924-16-3)
N-Nitrosodiethylamine (55-18-5)
N-Nitrosomethylethylamine (10595-95-6)
N-Nitrosomorpholine (59-89-2)
N-Nitrosopiperidine (100-75-4)
N-Nitrosopyrrolidine (930-55-2)
5-Nitro-o-toluidine (99-55-8)
1,4-Phenylenediamine (106-50-3)
2-Picoline (109-06-8)
o-Toluidine (95-53-4)

32460: Methapyrilene Standard
Methapyrilene hydrochloride (135-23-9)

31806: Appendix IX Mix #2
Acetophenone (98-86-2)
Aramite (140-57-8)
Atrazine (1912-24-9)
Benzaldehyde (100-52-7)
Biphenyl (92-52-4)
ε-Caprolactam (105-60-2)
Chlorobenzilate (510-15-6)
1-Chloronaphthalene (90-13-1)
Diallate (2303-16-4)
Dibenz[a,j]acridine (224-42-0)
2,6-Dichlorophenol (87-65-0)
7,12-Dimethylbenz[a]anthracene (57-97-6)
1,4-Dioxane (123-91-1)
Diphenyl ether (101-84-8)
Ethyl methacrylate (97-63-2)
Ethyl methanesulfonate (62-50-0)
Hexachloropropene (1888-71-7)
Isodrin (465-73-6)
Isosafrole (cis & trans) (120-58-1)
Kepone (143-50-0)
3-Methylcholanthrene (56-49-5)
Methyl methanesulfonate (66-27-3)
1,4-Naphthoquinone (130-15-4)
4-Nitroquinoline-N-oxide (56-57-5)
Pentachlorobenzene (608-93-5)
Pentachloroethane (76-01-7)
Pentachloronitrobenzene (Quintozene) (82-68-8)
Phenacetin (62-44-2)
Propyzamide (23950-58-5)
Safrole (94-59-7)
1,2,4,5-Tetrachlorobenzene (95-94-3)
1,3,5-Trinitrobenzene (99-35-4)

*1,2-diphenylhydrazine (8270-listed analyte) decomposes to azobenzene (mix component) in the injector.

N-Nitrosodiphenylamine is a reactive species that can initiate premature decomposition of other compounds in the mix. For these reasons, diphenylamine is used in the preparation of this mixture.

Specifications

Product Specifications
Catalog No.
31815
Product Name
8270/Appendix IX Kit