![Restek](/file/general/restek-logo.png)
Home / Reference Standards / Multi-Component / Arizona Pesticide Standard #4, 80-800 µg/mL, Acetonitrile, 1 mL/ampul
![Restek](/file/general/restek-logo.png)
![Arizona Pesticide Standard #4, 80-800 µg/mL, Acetonitrile, 1 mL/ampul Arizona Pesticide Standard #4, 80-800 µg/mL, Acetonitrile, 1 mL/ampul](/ccstore/v1/images/?source=/file/v7839387720295474101/products/ampul-0to2ml_ph_so_arm.jpg&height=475&width=475&quality=0.8&outputFormat=JPEG)
Arizona Pesticide Standard #4, 80-800 µg/mL, Acetonitrile, 1 mL/ampul
Catalog No. 32604
![Arizona Pesticide Standard #4, 80-800 µg/mL, Acetonitrile, 1 mL/ampul](/ccstore/v1/images/?source=/file/v7839387720295474101/products/ampul-0to2ml_ph_so_arm.jpg&height=200&width=200)
Arizona Pesticide Standard #4, 80-800 µg/mL, Acetonitrile, 1 mL/ampul
Overview
Features & Benefits
- 16-component mix provides analytical flexibility for constructing calibration curves or spiking sample matrices—saving time and reducing cost.
- Individual compound concentration aligns with state-specific compound action limits.
- Two independently produced lots available.
- Verified composition and stability ensures long-lasting shelf life.
- Formulated for Arizona cannabis regulations; can be used to meet other government or in-house method requirements.
Description
Compound | CAS# | Concentration |
---|---|---|
Azoxystrobin | 131860-33-8 | 80 µg/mL |
Boscalid | 188425-85-6 | 160 µg/mL |
Chlorantraniliprole* | 500008-45-7 | 80 µg/mL |
Chlorfenapyr | 122453-73-0 | 400 µg/mL |
Daminozide* | 1596-84-5 | 400 µg/mL |
(E)-Fenpyroximate | 134098-61-6 | 160 µg/mL |
Flonicamid | 158062-67-0 | 400 µg/mL |
Hexythiazox | 78587-05-0 | 400 µg/mL |
Kresoxim methyl | 143390-89-0 | 160 µg/mL |
Metalaxyl | 57837-19-1 | 80 µg/mL |
Piperonyl butoxide | 51-03-6 | 800 µg/mL |
Pyridaben | 96489-71-3 | 80 µg/mL |
Spiromesifen | 283594-90-1 | 80 µg/mL |
Spirotetramat | 203313-25-1 | 80 µg/mL |
Spiroxamine | 118134-30-8 | 160 µg/mL |
Trifloxystrobin | 141517-21-7 | 80 µg/mL |
*Reference materials containing chlorantraniliprole (500008-45-7) and daminozide (1596-84-5) must be sonicated for a minimum of 60 minutes prior to opening the ampul. Because each ultrasonic bath operates at a different energy level, 60 minutes is a guideline only. Longer sonication time will not affect product quality. These precautions apply to working solutions prepared in your laboratory as well. The amount of compound that precipitates depends on concentration and temperature. If you store your standards, even dilute solutions, at a temperature well below the label recommendation, allow extra sonication time.
Specifications
Product Specifications
Catalog No.
32604
Product Name
Arizona Pesticide Standard #4, 80-800 µg/mL, Acetonitrile, 1 mL/ampul