Restek
Home / Reference Standards / Multi-Component / Oregon Pesticide Standard #5, 600 µg/mL, Acetonitrile, 1 mL/ampul
Restek
Oregon Pesticide Standard #5, 600 µg/mL, Acetonitrile, 1 mL/ampul
  1. Oregon Pesticide Standard #5, 600 µg/mL, Acetonitrile, 1 mL/ampul

Oregon Pesticide Standard #5, 600 µg/mL, Acetonitrile, 1 mL/ampul

Catalog No. 32590
$140.00
Shipping Note
Access your CofA online at www.restek.com/documentation
Oregon Pesticide Standard #5, 600 µg/mL, Acetonitrile, 1 mL/ampul

Oregon Pesticide Standard #5, 600 µg/mL, Acetonitrile, 1 mL/ampul

$140.00

Overview

Features & Benefits
  • Meet specific cannabis pesticide residue analysis needs of Oregon, Michigan, and Washington—and states with similar pesticide residue regulations/programs.
  • Verified composition and stability.
  • 59 compounds in 6 x 1 mL ampules at 600 µg/mL—resulting in a convenient 100 µg/mL solution when blended immediately before use.
  • Prepared stock product eliminates the need for in-house standards preparation.
Description

Oregon Cannabis Pesticide Standards meet the specific cannabis pesticide residue analysis needs of Oregon—and states with similar pesticide residue regulations/programs. Dissolved in acetonitrile and formulated for stability, the 59 compounds are separated into 6 x 1 mL solutions with individual analyte concentrations of 600 µg/mL—resulting in a convenient 100 µg/mL solution when blended immediately before use. Designed with quality and convenience in mind, this set of standards eliminates the need for in-house standards preparation. Restek’s Oregon Pesticide Standards are certified reference materials (CRM) manufactured and QC-tested in ISO-accredited labs.

Compound CAS#
Bifenthrin 82657-04-3
Cyfluthrin 68359-37-5
Cypermethrin 52315-07-8
Etofenprox 80844-07-1
Permethrin (cis & trans) 52645-53-1
Prallethrin 23031-36-9
Pyrethrins* 8003-34-7

 

*This reference material contains pyrethrins, a technical mixture that is composed of six active insecticidal compounds. The ratio of each of the six compounds in this specific mixture is provided in the order they have eluted under the run conditions listed on the certificate. Only the peak corresponding to the pyrethrin compound with the highest signal intensity is labeled on the chromatogram. Due to the nature of pyrethrins, lot-to-lot variation in composition and purity may be observed based on raw material source.

Specifications

Product Specifications
Catalog No.
32590
Product Name
Oregon Pesticide Standard #5, 600 µg/mL, Acetonitrile, 1 mL/ampul
Custom Product Request
Custom Product Request

Not able to find the product looking for? You can request a custom product just by filling in a form