Restek
Home / Reference Standards / Multi-Component / New York Pesticide Kit, 1 mL/ampul, 8 ampuls/kit
Restek
Featured
New York Pesticide Kit, 1 mL/ampul, 8 ampuls/kit
  1. New York Pesticide Kit, 1 mL/ampul, 8 ampuls/kit

New York Pesticide Kit, 1 mL/ampul, 8 ampuls/kit

Catalog No. 32605
$640.00
Shipping Note
Access your CofA online at www.restek.com/documentation
New York Pesticide Kit, 1 mL/ampul, 8 ampuls/kit

New York Pesticide Kit, 1 mL/ampul, 8 ampuls/kit

$640.00

Overview

Features & Benefits
  • 70-component kit provides analytical flexibility for constructing calibration curves or spiking sample matrices—saving time and reducing cost.
  • Designed to create a high concentration working standard when all ampuls are combined.
  • Two independently produced lots available.
  • Verified composition and stability ensures long-lasting shelf life.
  • Formulated for New York cannabis regulations; can be used to meet other government or in-house method requirements.
Description

Contains 1 ampul of each of the following. 1 mL/ampul

Cat.# 32606: New York Pesticide Standard #1

Compound CAS#
Acephate 30560-19-1
Aldicarb 116-06-3
Bifenazate 149877-41-8
Carbaryl (Sevin) 63-25-2
Carbofuran 1563-66-2
Chlorpyrifos 2921-88-2
Coumaphos 56-72-4
Diazinon 333-41-5
Dichlorvos (DDVP) 62-73-7
Dimethoate 60-51-5
Ethoprophos 13194-48-4
Fenoxycarb 72490-01-8
Malathion 121-75-5
Methiocarb 2032-65-7
Methomyl 16752-77-5
Methyl parathion 298-00-0
Mevinphos 7786-34-7
Naled 300-76-5
Oxamyl 23135-22-0
Phosmet 732-11-6
Propoxur (Baygon) 114-26-1

 

Cat.# 32607: New York Pesticide Standard #2

Compound CAS#
Abamectin 71751-41-2
Acequinocyl 57960-19-7
Bifenthrin 82657-04-3
Cyfluthrin 68359-37-5
Cypermethrin 52315-07-8
Etofenprox 80844-07-1
Permethrin (cis & trans) 52645-53-1
Prallethrin 23031-36-9
Pyrethrins* 8003-34-7
Spinetoram (J&L) 935545-74-7
Spinosad 168316-95-8

 

Cat.# 32608: New York Pesticide Standard #3

Compound CAS#
Acetamiprid 135410-20-7
Chlordane 57-74-9
Clofentezine 74115-24-5
Etoxazole 153233-91-1
Fipronil 120068-37-3
Fludioxonil 131341-86-1
Imazalil 35554-44-0
Imidacloprid 138261-41-3
Myclobutanil 88671-89-0
Paclobutrazol 76738-62-0
Pentachloronitrobenzene (Quintozene) 82-68-8
Propiconazole (Tilt) 60207-90-1
Tebuconazole 107534-96-3
Thiacloprid 111988-49-9
Thiamethoxam 153719-23-4

 

Cat.# 32609: New York Pesticide Standard #4

Compound CAS#
Azoxystrobin 131860-33-8
Boscalid 188425-85-6
Chlorantraniliprole** 500008-45-7
Chlorfenapyr 122453-73-0
Daminozide** 1596-84-5
Dimethomorph 110488-70-5
Fenhexamid 126833-17-8
Fenpyroximate 111812-58-9
Flonicamid 158062-67-0
Hexythiazox 78587-05-0
Kresoxim methyl 143390-89-0
Metalaxyl 57837-19-1
MGK-264 113-48-4
Piperonyl butoxide 51-03-6
Pyridaben 96489-71-3
Spiromesifen 283594-90-1
Spirotetramat 203313-25-1
Spiroxamine 118134-30-8
Trifloxystrobin 141517-21-7

 

Cat.# 32610: Captan Standard

Compound CAS#
Captan 133-06-2

 

Cat.# 32611: Azadirachtin Standard

Compound CAS#
Azadirachtin 11141-17-6

 

Cat.# 32612: 3-Indolebutyric Acid Standard

Compound CAS#
3-Indolebutyric Acid 133-32-4

 

Cat.# 32613: Chlormequat Standard

Compound CAS#
Chlormequat chloride 999-81-5

 

*This reference material contains pyrethrins, a technical mixture that is composed of six active insecticidal compounds. The ratio of each of the six compounds in this specific mixture are provided in the order they have eluted under the run conditions listed on the certificate. Only the peak corresponding to the pyrethrin compound with the highest signal intensity is labeled on the chromatogram. Due to the nature of pyrethrins, lot-to-lot variation in composition and purity may be observed based on raw material source.

This reference material contains both the Spinetoram J and L isomers (187166-40-1 and 187166-15-0); however, CAS# 935545-74-7 is displayed on the certificate as this is the neat material dissolved in the solution. CAS# 935545-74-7 is a blend of Spinetoram J and L, and the ratio of each material isomer are displayed on your certificate of analysis.

This reference material contains Spinosad A and D isomers (131929-60-7 and 131929-63-0); however, CAS# 168316-95-8 is displayed on the certificate as this is the neat material dissolved in the solution. CAS# 168316-95-8 is a blend of Spinosad A and D, and the ratio of each material isomer are displayed on your certificate of analysis.

**Reference materials containing chlorantraniliprole (500008-45-7) and daminozide (1596-84-5) must be sonicated for a minimum of 60 minutes prior to opening the ampul. Because each ultrasonic bath operates at a different energy level, 60 minutes is a guideline only. Longer sonication time will not affect product quality. These precautions apply to working solutions prepared in your laboratory as well. The amount of compound that precipitates depends on concentration and temperature. If you store your standards, even dilute solutions, at a temperature well below the label recommendation, allow extra sonication time.

Specifications

Product Specifications
Catalog No.
32605
Product Name
New York Pesticide Kit, 1 mL/ampul, 8 ampuls/kit
Custom Product Request
Custom Product Request

Not able to find the product looking for? You can request a custom product just by filling in a form